Ballot Results
Ballot Name:
2022-01 Reporting ACE Definition and Associated Terms Modified - Disturbance FN 2 DEF
Voting Start Date:
12/11/2023 11:37:26 AM
Voting End Date:
12/20/2023 8:00:00 PM
Ballot Type:
DEF
Ballot Activity:
FN
Ballot Series:
2
Total # Votes:
208
Total Ballot Pool:
235
Quorum:
88.51
Quorum Established Date:
12/11/2023 2:35:45 PM
Weighted Segment Value:
99.61
Segment | Ballot Pool | Segment Weight | Affirmative Votes | Affirmative Fraction | Negative Votes w/ Comment | Negative Fraction w/ Comment | Negative Votes w/o Comment | Abstain | No Vote |
---|---|---|---|---|---|---|---|---|---|
Segment: 1 | 65 | 1 | 50 | 1 | 0 | 0 | 0 | 4 | 11 |
Segment: 2 | 8 | 0.6 | 6 | 0.6 | 0 | 0 | 0 | 0 | 2 |
Segment: 3 | 52 | 1 | 45 | 0.978 | 1 | 0.022 | 0 | 3 | 3 |
Segment: 4 | 9 | 0.5 | 5 | 0.5 | 0 | 0 | 0 | 1 | 3 |
Segment: 5 | 52 | 1 | 40 | 1 | 0 | 0 | 0 | 7 | 5 |
Segment: 6 | 43 | 1 | 35 | 1 | 0 | 0 | 0 | 5 | 3 |
Segment: 7 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Segment: 8 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Segment: 9 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Segment: 10 | 6 | 0.5 | 5 | 0.5 | 0 | 0 | 0 | 1 | 0 |
Totals: | 235 | 5.6 | 186 | 5.578 | 1 | 0.022 | 0 | 21 | 27 |
Ballot Pool Members
Segment | Organization | Voter | Designated Proxy | Ballot | NERC Memo |
---|---|---|---|---|---|
1 | Tennessee Valley Authority | David Plumb | Affirmative | N/A | |
1 | NiSource - Northern Indiana Public Service Co. | Alison Nickells | Affirmative | N/A | |
1 | Berkshire Hathaway Energy - MidAmerican Energy Co. | Terry Harbour | Affirmative | N/A | |
6 | Con Ed - Consolidated Edison Co. of New York | Jason Chandler | Affirmative | N/A | |
6 | Tennessee Valley Authority | Armando Rodriguez | Affirmative | N/A | |
1 | NB Power Corporation | Jeffrey Streifling | Affirmative | N/A | |
1 | Manitoba Hydro | Nazra Gladu | Affirmative | N/A | |
1 | Evergy | Kevin Frick | Alan Kloster | Affirmative | N/A |
1 | Con Ed - Consolidated Edison Co. of New York | Dermot Smyth | Affirmative | N/A | |
3 | Tennessee Valley Authority | Ian Grant | Affirmative | N/A | |
4 | FirstEnergy - FirstEnergy Corporation | Mark Garza | Abstain | N/A | |
6 | Constellation | Kimberly Turco | Abstain | N/A | |
5 | Manitoba Hydro | Kristy-Lee Young | Affirmative | N/A | |
3 | Arkansas Electric Cooperative Corporation | Ayslynn Mcavoy | Affirmative | N/A | |
6 | Manitoba Hydro | Brandin Stoesz | Affirmative | N/A | |
6 | Arkansas Electric Cooperative Corporation | Bruce Walkup | Abstain | N/A | |
5 | Lincoln Electric System | Brittany Millard | Affirmative | N/A | |
3 | WEC Energy Group, Inc. | Christine Kane | Affirmative | N/A | |
6 | Southern Company - Southern Company Generation | Ron Carlsen | Affirmative | N/A | |
3 | Southern Company - Alabama Power Company | Joel Dembowski | Affirmative | N/A | |
5 | Southern Company - Southern Company Generation | Leslie Burke | Affirmative | N/A | |
1 | Southern Company - Southern Company Services, Inc. | Matt Carden | Affirmative | N/A | |
6 | Evergy | Jennifer Flandermeyer | Alan Kloster | Affirmative | N/A |
1 | Western Area Power Administration | Ben Hammer | Affirmative | N/A | |
5 | Bonneville Power Administration | Juergen Bermejo | Affirmative | N/A | |
10 | ReliabilityFirst | Tyler Schwendiman | Affirmative | N/A | |
1 | BC Hydro and Power Authority | Adrian Andreoiu | Affirmative | N/A | |
6 | WEC Energy Group, Inc. | David Boeshaar | Affirmative | N/A | |
5 | Con Ed - Consolidated Edison Co. of New York | Michelle Pagano | Affirmative | N/A | |
1 | Associated Electric Cooperative, Inc. | Mark Riley | Affirmative | N/A | |
6 | Western Area Power Administration | Jennifer Neville | Affirmative | N/A | |
6 | Omaha Public Power District | Shonda McCain | Affirmative | N/A | |
3 | FirstEnergy - FirstEnergy Corporation | Aaron Ghodooshim | Abstain | N/A | |
2 | California ISO | Darcy O'Connell | Affirmative | N/A | |
3 | Bonneville Power Administration | Ron Sporseen | Affirmative | N/A | |
1 | Omaha Public Power District | Doug Peterchuck | Affirmative | N/A | |
3 | Manitoba Hydro | Mike Smith | Affirmative | N/A | |
6 | Bonneville Power Administration | Tanner Brier | Affirmative | N/A | |
5 | Evergy | Jeremy Harris | Alan Kloster | Affirmative | N/A |
3 | APS - Arizona Public Service Co. | Jessica Lopez | Affirmative | N/A | |
5 | APS - Arizona Public Service Co. | Andrew Smith | Affirmative | N/A | |
3 | Ameren - Ameren Services | David Jendras Sr | Affirmative | N/A | |
6 | Ameren - Ameren Services | Robert Quinlivan | Affirmative | N/A | |
3 | Santee Cooper | Vicky Budreau | Affirmative | N/A | |
5 | Santee Cooper | Don Cribb | Affirmative | N/A | |
5 | Ameren - Ameren Missouri | Sam Dwyer | Affirmative | N/A | |
1 | APS - Arizona Public Service Co. | Daniela Atanasovski | Affirmative | N/A | |
6 | APS - Arizona Public Service Co. | Marcus Bortman | Affirmative | N/A | |
5 | Tri-State G and T Association, Inc. | Sergio Banuelos | Affirmative | N/A | |
1 | Santee Cooper | Chris Wagner | Affirmative | N/A | |
6 | Santee Cooper | Marty Watson | Affirmative | N/A | |
5 | Dairyland Power Cooperative | Tommy Drea | Affirmative | N/A | |
1 | PPL Electric Utilities Corporation | Michelle McCartney Longo | Affirmative | N/A | |
3 | Con Ed - Consolidated Edison Co. of New York | Peter Yost | Affirmative | N/A | |
6 | FirstEnergy - FirstEnergy Corporation | Stacey Sheehan | Abstain | N/A | |
4 | WEC Energy Group, Inc. | Matthew Beilfuss | Affirmative | N/A | |
5 | Xcel Energy, Inc. | Gerry Huitt | Affirmative | N/A | |
6 | PPL - Louisville Gas and Electric Co. | Linn Oelker | Affirmative | N/A | |
3 | Avista - Avista Corporation | Robert Follini | Affirmative | N/A | |
3 | Los Angeles Department of Water and Power | Tony Skourtas | Abstain | N/A | |
1 | Xcel Energy, Inc. | Eric Barry | Affirmative | N/A | |
6 | Los Angeles Department of Water and Power | Anton Vu | Abstain | N/A | |
1 | Tri-State G and T Association, Inc. | Donna Wood | Affirmative | N/A | |
5 | Los Angeles Department of Water and Power | Glenn Barry | Abstain | N/A | |
3 | Evergy | Marcus Moor | Alan Kloster | Affirmative | N/A |
2 | Southwest Power Pool, Inc. (RTO) | Joshua Phillips | Affirmative | N/A | |
4 | Alliant Energy Corporation Services, Inc. | Larry Heckert | Affirmative | N/A | |
5 | Greybeard Compliance Services, LLC | Mike Gabriel | Abstain | N/A | |
1 | FirstEnergy - FirstEnergy Corporation | Theresa Ciancio | Abstain | N/A | |
2 | ISO New England, Inc. | John Pearson | Kathleen Goodman | None | N/A |
3 | Xcel Energy, Inc. | Nicholas Friebel | Affirmative | N/A | |
6 | Dominion - Dominion Resources, Inc. | Sean Bodkin | Affirmative | N/A | |
6 | Platte River Power Authority | Sabrina Martz | Affirmative | N/A | |
2 | PJM Interconnection, L.L.C. | Thomas Foster | Elizabeth Davis | Affirmative | N/A |
2 | Midcontinent ISO, Inc. | Bobbi Welch | Affirmative | N/A | |
2 | Independent Electricity System Operator | Helen Lainis | Affirmative | N/A | |
1 | Muscatine Power and Water | Andrew Kurriger | Affirmative | N/A | |
5 | Avista - Avista Corporation | Glen Farmer | Affirmative | N/A | |
1 | Platte River Power Authority | Marissa Archie | Affirmative | N/A | |
3 | Dominion - Dominion Virginia Power | Victoria Crider | Affirmative | N/A | |
1 | Dairyland Power Cooperative | Karrie Schuldt | Affirmative | N/A | |
3 | Omaha Public Power District | David Heins | Affirmative | N/A | |
1 | OGE Energy - Oklahoma Gas and Electric Co. | Terri Pyle | Affirmative | N/A | |
10 | Northeast Power Coordinating Council | Gerry Dunbar | Abstain | N/A | |
6 | Entergy | Julie Hall | Affirmative | N/A | |
3 | NiSource - Northern Indiana Public Service Co. | Steven Taddeucci | Affirmative | N/A | |
1 | Dominion - Dominion Virginia Power | Steven Belle | Affirmative | N/A | |
3 | Salt River Project | Mathew Weber | Affirmative | N/A | |
3 | OGE Energy - Oklahoma Gas and Electric Co. | Donald Hargrove | Affirmative | N/A | |
3 | Snohomish County PUD No. 1 | Holly Chaney | Affirmative | N/A | |
5 | Salt River Project | Jennifer Bennett | Affirmative | N/A | |
5 | Berkshire Hathaway - NV Energy | Dwanique Spiller | Affirmative | N/A | |
1 | PNM Resources - Public Service Company of New Mexico | Lynn Goldstein | Affirmative | N/A | |
6 | OGE Energy - Oklahoma Gas and Electric Co. | Ashley F Stringer | Affirmative | N/A | |
1 | Los Angeles Department of Water and Power | faranak sarbaz | Abstain | N/A | |
5 | Platte River Power Authority | Jon Osell | Affirmative | N/A | |
5 | BC Hydro and Power Authority | Quincy Wang | Affirmative | N/A | |
1 | IDACORP - Idaho Power Company | Sean Steffensen | None | N/A | |
6 | Lakeland Electric | Paul Shipps | None | N/A | |
3 | Platte River Power Authority | Richard Kiess | Affirmative | N/A | |
1 | International Transmission Company Holdings Corporation | Michael Moltane | Gail Elliott | Affirmative | N/A |
5 | FirstEnergy - FirstEnergy Corporation | Matthew Augustin | Abstain | N/A | |
6 | Tacoma Public Utilities (Tacoma, WA) | Terry Gifford | Jennie Wike | None | N/A |
5 | Seminole Electric Cooperative, Inc. | Melanie Wong | None | N/A | |
5 | Constellation | Alison MacKellar | Abstain | N/A | |
5 | Dominion - Dominion Resources, Inc. | Anna Salmon | Affirmative | N/A | |
4 | Tacoma Public Utilities (Tacoma, WA) | Hien Ho | Jennie Wike | None | N/A |
1 | Public Utility District No. 1 of Snohomish County | Alyssia Rhoads | Affirmative | N/A | |
5 | WEC Energy Group, Inc. | Michelle Hribar | Affirmative | N/A | |
4 | Austin Energy | Tony Hua | None | N/A | |
4 | Public Utility District No. 1 of Snohomish County | John D. Martinsen | Affirmative | N/A | |
6 | Portland General Electric Co. | Stefanie Burke | Affirmative | N/A | |
1 | Nebraska Public Power District | Jamison Cawley | Affirmative | N/A | |
5 | Imperial Irrigation District | Tino Zaragoza | Affirmative | N/A | |
5 | Public Utility District No. 1 of Snohomish County | Becky Burden | Affirmative | N/A | |
6 | Snohomish County PUD No. 1 | John Liang | Affirmative | N/A | |
1 | Ameren - Ameren Services | Tamara Evey | Affirmative | N/A | |
3 | Duke Energy - Florida Power Corporation | Marcelo Pesantez | Affirmative | N/A | |
6 | Duke Energy | John Sturgeon | Affirmative | N/A | |
3 | Nebraska Public Power District | Tony Eddleman | Affirmative | N/A | |
4 | Public Utility District No. 2 of Grant County, Washington | Karla Weaver | Affirmative | N/A | |
3 | Tri-State G and T Association, Inc. | Ryan Walter | None | N/A | |
1 | OTP - Otter Tail Power Company | Charles Wicklund | None | N/A | |
5 | OTP - Otter Tail Power Company | Stacy Wahlund | None | N/A | |
3 | PPL - Louisville Gas and Electric Co. | James Frank | Affirmative | N/A | |
1 | Glencoe Light and Power Commission | Terry Volkmann | Affirmative | N/A | |
1 | Great River Energy | Gordon Pietsch | Affirmative | N/A | |
3 | Great River Energy | Michael Brytowski | Affirmative | N/A | |
6 | NiSource - Northern Indiana Public Service Co. | Dmitriy Bazylyuk | Affirmative | N/A | |
10 | Western Electricity Coordinating Council | Steven Rueckert | Affirmative | N/A | |
5 | Duke Energy | Dale Goodwine | Affirmative | N/A | |
5 | Nebraska Public Power District | Ronald Bender | Affirmative | N/A | |
6 | Powerex Corporation | Raj Hundal | Affirmative | N/A | |
1 | National Grid USA | Michael Jones | Affirmative | N/A | |
1 | NextEra Energy - Florida Power and Light Co. | Silvia Mitchell | Abstain | N/A | |
1 | Arizona Electric Power Cooperative, Inc. | Jennifer Bray | Affirmative | N/A | |
3 | Associated Electric Cooperative, Inc. | Todd Bennett | Affirmative | N/A | |
1 | Duke Energy | Katherine Street | Affirmative | N/A | |
5 | OGE Energy - Oklahoma Gas and Electric Co. | Patrick Wells | Affirmative | N/A | |
6 | NextEra Energy - Florida Power and Light Co. | Justin Welty | Abstain | N/A | |
6 | Imperial Irrigation District | Diana Torres | Affirmative | N/A | |
5 | National Grid USA | Robin Berry | Affirmative | N/A | |
1 | Tacoma Public Utilities (Tacoma, WA) | John Merrell | Jennie Wike | None | N/A |
5 | PSEG Nuclear LLC | Tim Kucey | Affirmative | N/A | |
3 | Seminole Electric Cooperative, Inc. | Marc Sedor | None | N/A | |
2 | Electric Reliability Council of Texas, Inc. | Kennedy Meier | Affirmative | N/A | |
3 | PSEG - Public Service Electric and Gas Co. | Christopher Murphy | Affirmative | N/A | |
6 | PSEG - PSEG Energy Resources and Trade LLC | Laura Wu | Affirmative | N/A | |
6 | Sacramento Municipal Utility District | Charles Norton | Tim Kelley | Affirmative | N/A |
1 | Avista - Avista Corporation | Mike Magruder | None | N/A | |
10 | Midwest Reliability Organization | Mark Flanary | Affirmative | N/A | |
5 | NextEra Energy | Richard Vendetti | Abstain | N/A | |
5 | NiSource - Northern Indiana Public Service Co. | Kathryn Tackett | Affirmative | N/A | |
3 | NextEra Energy - Florida Power and Light Co. | Karen Demos | Abstain | N/A | |
1 | Bonneville Power Administration | Kamala Rogers-Holliday | Affirmative | N/A | |
3 | Black Hills Corporation | Josh Combs | Affirmative | N/A | |
6 | Black Hills Corporation | Rachel Schuldt | Affirmative | N/A | |
3 | Muscatine Power and Water | Seth Shoemaker | Affirmative | N/A | |
5 | Muscatine Power and Water | Chance Back | Affirmative | N/A | |
6 | Muscatine Power and Water | Nicholas Burns | Affirmative | N/A | |
5 | Pacific Gas and Electric Company | Tyler Brun | None | N/A | |
5 | Sacramento Municipal Utility District | Ryder Couch | Tim Kelley | Affirmative | N/A |
4 | Sacramento Municipal Utility District | Foung Mua | Tim Kelley | Affirmative | N/A |
3 | OTP - Otter Tail Power Company | Wendi Olson | None | N/A | |
1 | Exelon | Daniel Gacek | Rajesh Geevarghese | Affirmative | N/A |
3 | Exelon | Kinte Whitehead | Affirmative | N/A | |
1 | American Transmission Company, LLC | Amy Wilke | None | N/A | |
6 | Xcel Energy, Inc. | Carrie Dixon | Joseph Gatten | Affirmative | N/A |
1 | Unisource - Tucson Electric Power Co. | Jessica Cordero | None | N/A | |
6 | Great River Energy | Brian Meloy | Affirmative | N/A | |
5 | Associated Electric Cooperative, Inc. | Chuck Booth | Affirmative | N/A | |
3 | M and A Electric Power Cooperative | Gary Dollins | Affirmative | N/A | |
1 | KAMO Electric Cooperative | Micah Breedlove | None | N/A | |
3 | NW Electric Power Cooperative, Inc. | Heath Henry | Affirmative | N/A | |
3 | KAMO Electric Cooperative | Tony Gott | Affirmative | N/A | |
3 | Sho-Me Power Electric Cooperative | Jarrod Murdaugh | Affirmative | N/A | |
5 | Colorado Springs Utilities | Jeffrey Icke | Abstain | N/A | |
1 | M and A Electric Power Cooperative | William Price | Affirmative | N/A | |
1 | Seminole Electric Cooperative, Inc. | Kristine Ward | None | N/A | |
1 | Eversource Energy | Joshua London | None | N/A | |
1 | Central Iowa Power Cooperative | Kevin Lyons | Affirmative | N/A | |
5 | Black Hills Corporation | Sheila Suurmeier | Affirmative | N/A | |
3 | Central Electric Power Cooperative (Missouri) | Adam Weber | Affirmative | N/A | |
4 | Seminole Electric Cooperative, Inc. | Ken Habgood | None | N/A | |
1 | Northeast Missouri Electric Power Cooperative | Brett Douglas | Affirmative | N/A | |
3 | Entergy | James Keele | Affirmative | N/A | |
5 | Entergy - Entergy Services, Inc. | Gail Golden | Affirmative | N/A | |
1 | Imperial Irrigation District | Jesus Sammy Alcaraz | Affirmative | N/A | |
3 | Sacramento Municipal Utility District | Nicole Looney | Tim Kelley | Affirmative | N/A |
1 | Allete - Minnesota Power, Inc. | Hillary Creurer | None | N/A | |
6 | Lincoln Electric System | Eric Ruskamp | Affirmative | N/A | |
3 | Lincoln Electric System | Sam Christensen | Affirmative | N/A | |
1 | N.W. Electric Power Cooperative, Inc. | Mark Ramsey | Affirmative | N/A | |
1 | Austin Energy | Thomas Standifur | Abstain | N/A | |
1 | Sacramento Municipal Utility District | Wei Shao | Tim Kelley | Affirmative | N/A |
1 | Black Hills Corporation | Micah Runner | Affirmative | N/A | |
3 | Imperial Irrigation District | George Kirschner | Affirmative | N/A | |
1 | New York Power Authority | Daniel Valle | Affirmative | N/A | |
6 | New York Power Authority | Shelly Dineen | Affirmative | N/A | |
5 | Ontario Power Generation Inc. | Constantin Chitescu | Abstain | N/A | |
6 | Public Utility District No. 2 of Grant County, Washington | Mike Stussy | Affirmative | N/A | |
10 | SERC Reliability Corporation | Dave Krueger | Affirmative | N/A | |
1 | Pacific Gas and Electric Company | Marco Rios | Michael Johnson | Affirmative | N/A |
5 | Orlando Utilities Commission | Dania Colon | Affirmative | N/A | |
5 | PPL - Louisville Gas and Electric Co. | Julie Hostrander | Affirmative | N/A | |
1 | Lincoln Electric System | Josh Johnson | Affirmative | N/A | |
3 | National Grid USA | Brian Shanahan | Affirmative | N/A | |
1 | Entergy | Brian Lindsey | Affirmative | N/A | |
3 | New York Power Authority | Richard Machado | Affirmative | N/A | |
3 | Southern Indiana Gas and Electric Co. | Ryan Snyder | Affirmative | N/A | |
3 | Berkshire Hathaway Energy - MidAmerican Energy Co. | Joseph Amato | Affirmative | N/A | |
5 | Tacoma Public Utilities (Tacoma, WA) | Ozan Ferrin | Jennie Wike | None | N/A |
1 | Salt River Project | Laura Somak | Affirmative | N/A | |
1 | CenterPoint Energy Houston Electric, LLC | Daniela Hammons | Affirmative | N/A | |
6 | Salt River Project | Timothy Singh | Affirmative | N/A | |
1 | Hydro One Networks, Inc. | Alain Mukama | Affirmative | N/A | |
5 | Public Utility District No. 1 of Chelan County | Rebecca Wickel | Affirmative | N/A | |
6 | Public Utility District No. 1 of Chelan County | Robert Witham | Affirmative | N/A | |
3 | Public Utility District No. 1 of Chelan County | Joyce Gundry | Affirmative | N/A | |
10 | Texas Reliability Entity, Inc. | Rachel Coyne | Affirmative | N/A | |
5 | Great River Energy | Jacalynn Bentz | Affirmative | N/A | |
6 | Southern Indiana Gas and Electric Co. | Kati Barr | Affirmative | N/A | |
3 | Pacific Gas and Electric Company | Sandra Ellis | Affirmative | N/A | |
3 | Northeast Missouri Electric Power Cooperative | Skyler Wiegmann | Affirmative | N/A | |
5 | Southern Indiana Gas and Electric Co. | Larry Rogers | Affirmative | N/A | |
1 | Public Utility District No. 1 of Chelan County | Diane E Landry | Affirmative | N/A | |
5 | Pattern Operators LP | George E Brown | Affirmative | N/A | |
2 | New York Independent System Operator | Gregory Campoli | None | N/A | |
5 | New York Power Authority | Zahid Qayyum | Affirmative | N/A | |
1 | Tallahassee Electric (City of Tallahassee, FL) | Scott Langston | Affirmative | N/A | |
5 | Choctaw Generation Limited Partnership, LLLP | Rob Watson | Affirmative | N/A | |
3 | Edison International - Southern California Edison Company | Romel Aquino | Negative | N/A | |
6 | Edison International - Southern California Edison Company | Stephanie Kenny | None | N/A | |
1 | Hydro-Quebec (HQ) | Nicolas Turcotte | None | N/A | |
5 | Hydro-Quebec (HQ) | Junji Yamaguchi | None | N/A |