2019-03 Cyber Security Supply Chain Risks | CIP-005-7, CIP-010-4, & CIP-013-2

Description:

Start Date: 01/27/2020
End Date: 03/11/2020

Associated Ballots:

Ballot Name Project Standard Pool Open Pool Close Voting Start Voting End
2019-03 Cyber Security Supply Chain Risks CIP-005-7, CIP-010-4, & CIP-013-2 IN 1 ST 2019-03 Cyber Security Supply Chain Risks CIP-005-7, CIP-010-4, & CIP-013-2 01/27/2020 02/25/2020 03/02/2020 03/11/2020

Filter:

Hot Answers

MidAmerican agrees with MRO NSRF comments.

Terry Harbour, On Behalf of: Berkshire Hathaway Energy - MidAmerican Energy Co., , Segments 1, 3

- 0 - 0

Please see comments submitted by Edison Electric Institute.

Kenya Streeter, Edison International - Southern California Edison Company, 6, 3/11/2020

- 0 - 0

Other Answers

Kevin Conway, Public Utility District No. 1 of Pend Oreille County, 1, 1/28/2020

- 0 - 0

The risk focus should be limited to controls only, not monitoring.

Tho Tran, 2/26/2020

- 0 - 0

Kelsi Rigby, 2/27/2020

- 0 - 0

Tim Womack, 3/2/2020

- 0 - 0

LaTroy Brumfield, American Transmission Company, LLC, 1, 3/2/2020

- 0 - 0

sean erickson, Western Area Power Administration, 1, 3/2/2020

- 1 - 0

NO.  Changes to these Standards are not needed at all!

Marty Hostler, Northern California Power Agency, 4, 3/2/2020

- 0 - 0

Changes to these Standards are not needed at all!

Dennis Sismaet, Northern California Power Agency, 6, 3/3/2020

- 0 - 0

Changes to these standards are not needed at all.

Scott Tomashefsky, 3/3/2020

- 0 - 0

Bruce Reimer, 3/5/2020

- 0 - 0

Duke Energy generally agrees with adding EACMS to the Supply Chain Standards as currently described above.

Duke Energy, Segment(s) 1, 5, 6, 3, 12/13/2019

- 0 - 0

We agree with the addition of EACMS (and PACS) to CIP-005-7 and CIP-013-2, but a close examination of the currently approved definition(s) of EACMS (and PACS) prevents them from being added to Medium Impact BES Cyber Systems in CIP-010-4 Requirement R1, Part 1.6 as proposed.

EACMS are currently defined as:

“Cyber Assets that perform electronic access control or electronic access monitoring of the Electronic Security Perimeter(s) or BES Cyber Systems. This includes Intermediate Systems.”

EACMS are tied to ESPs. ESPs only exist with respect to Medium Impact BES Cyber Systems connected using a routable protocol. EACMS monitor and control the EAP on an ESP, so only Medium Impact BES Cyber Systems with External Routable Connectivity apply.

We understand that Applicable Systems cannot simply be changed to “Medium Impact BES Cyber Systems with External Routable Connectivity” because that would take Medium Impact BES Cyber Systems out of scope.

We recommend, for clarity and consistency among CIP standards:

Insert:

“Medium Impact BES Cyber Systems with External Routable Connectivity and their associated:

1.  EACMS; and

2.  PACS”

Between High Impact and Medium Impact Applicable Systems in CIP-010-4 Requirement R1, Part 1.6.

Dana Klem, On Behalf of: MRO - MRO - Segments 1, 2, 3, 4, 5, 6

- 0 - 0

Anthony Jablonski, ReliabilityFirst , 10, 3/6/2020

- 0 - 0

GSOC and GTC respectfully reiterate the cooperative sector’s comments in response to the Commission’s Notice of Proposed Rulemaking regarding the dearth of reliability benefit associated with inclusion of those assets that provide only monitoring and logging functions and capabilities.  Review of the proposed revisions, however, confirms that they meet the FERC directive set forth in Order 850.  For the reasons cited in previous comments, GSOC and GTC continue to have reservations regarding the reliability benefit that the application of the CIP-013, CIP-005, and CIP-010 requirements to electronic access monitoring systems would contribute.  Moreover, GSOC and GTC also have concerns regarding: (1) the synergies between this project and other standards development projects that are evaluating the current definition of EACMS and (2) the reconciliation of the implementation of the directive with findings presented by NERC Staff in the NERC Supply Chain report “to include those systems that provide electronic access control (excluding monitoring and logging) to high and medium impact BES Cyber Systems.”  GSOC and GTC respectfully suggest that the ERO Enterprise and the SDT consider interdependencies between these efforts and evaluate opportunities to better integrate them to ensure that future standards and definition modifications do not beget the need for cyclical, periodic revisions to reconcile each new set of revisions proposed by these different, but inter-dependent projects.

Andrea Barclay, 3/6/2020

- 0 - 0

OPG supports RSC comments.

Constantin Chitescu, Ontario Power Generation Inc., 5, 3/6/2020

- 0 - 0

BPA believes there is the potential for the definitions and requirements to be in conflict with Project 2016-02, specifically where Project 2016-02 is working on definitions of EACMS vs EACS/EAMS to address different risk and security architecture in a virtualized environment. Project 2016-02 should be permitted to finish the work and have a planned implement date prior to another revision being implemented.

Andrea Jessup, On Behalf of: Bonneville Power Administration, WECC, Segments 1, 3, 5, 6

- 0 - 0

Jennifer Wright, Sempra - San Diego Gas and Electric, 5, 3/6/2020

- 0 - 0

David Reinecke, On Behalf of: Seminole Electric Cooperative, Inc., , Segments 1, 3, 4, 5, 6

- 0 - 0

We agree conceptually with including EACMS but need to assess the risk and implementation.

Leonard Kula, On Behalf of: Independent Electricity System Operator, , Segments 2

- 0 - 0

FE Voter, Segment(s) 1, 3, 5, 6, 4, 10/31/2019

- 0 - 0

PG&E agrees with the addition of EACMS but does not agree with the use of EACMS as currently defined in the “Applicable System Columns in Tables” section of the Standard.  Including EACMS which provides “access control”, “monitoring”, and “alerting” capabilities extend what FERC indicated in Order 850  which indicated only “access control”.  PG&E believes the risk of EACMS which “only” provides monitoring and alerting capabilities is not the same as those which provide “access control” and should be excluded from the Standard.  PG&E does indicate if an EACMS provides access control while at the same time monitoring and/or alerting capabilities it should be covered by the Standard. 

 

PG&E recommends the definition in the “Applicable System Columns in Tables” section be altered to indicate only those EACMS which provide “access control” and that EACMS that only provide monitoring and alerting be excluded.  A Technical Rationale document could be created to clearly indicate what type of EACMS would be covered with examples to help clarify any confusion.  A potential benefit in making the “Applicable Systems Column in Table” indicate EACMS with only “access control” is to the Project 2016-02 SDT working on the separation of EACMS into Cyber Assets for “access control” (EACS) and monitoring/alerting (EAMS).  A clear indication of “access control” in the Project 2019-03 modifications could make it easier for the Project 2016-02 SDT to make conforming changes to CIP-005, CIP-010, and CIP-013 once they are ready to complete the work on the EACMS separation.

PG&E All Segments, Segment(s) 1, 3, 5, 2/10/2020

- 1 - 0

Anton Vu, Los Angeles Department of Water and Power, 6, 3/9/2020

- 1 - 0

CenterPoint Energy Houston Electric, LLC (CEHE) supports the comments as submitted by the Edison Electric Institute.

Eli Rivera, On Behalf of: CenterPoint Energy Houston Electric, LLC, Texas RE, Segments NA - Not Applicable

- 0 - 0

Alliant Energy agrees with NSRF and EEI’s comments.

Jenifer Holmes, On Behalf of: Alliant Energy Corporation Services, Inc. - MRO, RF - Segments 4

- 0 - 0

Exelon is aligning with EEI's comments for this question.

Daniel Gacek, Exelon, 1, 3/9/2020

- 0 - 0

Please see comments submitted by Edison Electric Institute

Ayman Samaan, 3/9/2020

- 0 - 0

ISO-NE disagrees with adding EACMS and PACS to CIP-005. CIP-005 was intended for access to High and PCA systems. In fact,

EACMs are derived from the CIP-005 requirements.

The CIP standards and requirements are structured to address security concerns based on the criticality and risk to the

BES. EACMS and PACS do not incur the same security concerns and do not have the same criticality or risk to the BES;

therefore, EACMS and especially PACS should not be treated the same as High or Medium Impact systems that have a

direct correlation to the reliability of the BES. Additionally, the co-mingled definition of “access control and monitoring”

inherently elevates systems with monitoring only capability to a high-water mark, adding the need to incorporate

burdensome and costly controls to extremely low risk systems for little benefit.

John Galloway, On Behalf of: Michael Puscas, ISO New England, Inc., 2

- 0 - 0

Dania Colon, Orlando Utilities Commission, 5, 3/10/2020

- 0 - 0

ACES Standard Collaborations, Segment(s) 1, 3, 4, 5, 3/10/2020

- 0 - 0

Barry Jones, On Behalf of: Rosemary Jones, Western Area Power Administration, 1,6

- 0 - 0

Dmitriy Bazylyuk, 3/10/2020

- 0 - 0

Jamie Prater, 3/10/2020

- 0 - 0

We agree conceptually on the intent but we think that there is a need to better define the requirements. The added requirements are in the IRA section of CIP-005 R2, one could think that for accessing the EACMS an Intermediate system is required.

Nicolas Turcotte, Hydro-Qu?bec TransEnergie, 1, 3/10/2020

- 0 - 0

Although the CAISO acknowledges that EACMS are as important to protect as the BCS in line with the FERC Order, we recommend to wait on extending the program to EACMS until after the upcoming CIP-005-6, CIP-010-3 and CIP-013-1 standards have been in effect for at least a two years to allow for the processes and controls to mature, to obtain any key learnings from implementing these protections and from audit experiences including findings and areas of concerns identified by the  auditors. At that time the CAISO also proposes NERC issue a CIP-013-1 survey amongst the industry to collect recommendations for improvement of the industry’s supply chain security standard.

Monika Montez, On Behalf of: California ISO, WECC, Segments 2

- 0 - 0

Joshua Andersen, On Behalf of: Salt River Project, WECC, Segments 1, 3, 5, 6

- 0 - 0

Richard Jackson, U.S. Bureau of Reclamation, 1, 3/10/2020

- 0 - 0

Roger Fradenburgh, On Behalf of: Nicholas Lauriat, Network and Security Technologies, 1

- 0 - 0

MPC respectfully reiterates the cooperative sector’s comments in response to the Commission’s Notice of Proposed Rulemaking regarding the dearth of reliability benefit associated with inclusion of those assets that provide only monitoring and logging functions and capabilities.  Review of the proposed revisions, however, confirms that they meet the FERC directive set forth in Order 850.  For the reasons cited in previous comments, MPC continues to have reservations regarding the reliability benefit that the application of the CIP-013, CIP-005, and CIP-010 requirements to electronic access monitoring systems would contribute.  Moreover, MPC also has concerns regarding: (1) the synergies between this project and other standards development projects that are evaluating the current definition of EACMS and (2) the reconciliation of the implementation of the directive with findings presented by NERC Staff in the NERC Supply Chain report “to include those systems that provide electronic access control (excluding monitoring and logging) to high and medium impact BES Cyber Systems.”  MPC respectfully suggest that the ERO Enterprise and the SDT consider the codependent nature of these efforts and evaluate opportunities to better integrate them to ensure that future standards and definition modifications do not beget the need for cyclical, periodic revisions to reconcile each new set of revisions proposed by these different, but inter-dependent projects.

Andy Fuhrman, On Behalf of: Theresa Allard, Minnkota Power Cooperative Inc., 1

- 0 - 0

Carl Pineault, Hydro-Qu?bec Production, 5, 3/11/2020

- 0 - 0

Ameren agrees with and supports EEI comments.

David Jendras, Ameren - Ameren Services, 3, 3/11/2020

- 0 - 0

Glen Farmer, Avista - Avista Corporation, 5, 3/11/2020

- 0 - 0

GSOC and GTC respectfully reiterate the cooperative sector’s comments in response to the Commission’s Notice of Proposed Rulemaking regarding the dearth of reliability benefit associated with inclusion of those assets that provide only monitoring and logging functions and capabilities.  Review of the proposed revisions, however, confirms that they meet the FERC directive set forth in Order 850.  For the reasons cited in previous comments, GSOC and GTC continue to have reservations regarding the reliability benefit that the application of the CIP-013, CIP-005, and CIP-010 requirements to electronic access monitoring systems would contribute.  Moreover, GSOC and GTC also have concerns regarding: (1) the synergies between this project and other standards development projects that are evaluating the current definition of EACMS and (2) the reconciliation of the implementation of the directive with findings presented by NERC Staff in the NERC Supply Chain report “to include those systems that provide electronic access control (excluding monitoring and logging) to high and medium impact BES Cyber Systems.”  GSOC and GTC respectfully suggest that the ERO Enterprise and the SDT consider interdependencies between these efforts and evaluate opportunities to better integrate them to ensure that future standards and definition modifications do not beget the need for cyclical, periodic revisions to reconcile each new set of revisions proposed by these different, but inter-dependent projects.

Greg Davis, On Behalf of: Georgia Transmission Corporation, , Segments 1

- 0 - 0

Exelon has aligned with EEI's comment in response to this question.

Cynthia Lee, Exelon, 5, 3/11/2020

- 0 - 0

Exelon will align with EEI's comments in response to this question.

Becky Webb, Exelon, 6, 3/11/2020

- 0 - 0

Xcel Energy supports EEI comments on this question.  In addition, Xcel Energy suggests adding the following language after EACMS in that applicability column of CIP-005-6 R2.4 and R2.5, CIP-010-4 and CIP-013-2 “that perform the function of controlling electronic access.” Xcel Energy believes that this language would bring into scope all systems the perform access controls at an ESP, while excluding systems that only perform monitoring and or logging.

Making this change is supported by the Commission in Order 850 P55, where they state that “the standard drafting team that is formed in response to our present directive may determine…what EACMS functions are most important to the reliable operation of the Bulk-Power System and therefore should be included in the supply chain risk management Reliability Standard.” The limitation of EACMS is also supported by NERC in the Cyber Security Supply Chain Risks Staff Report where they state in the Recommended Actions to Address the Risks section of CH2, P9 that “upon evaluation of the supply chain-related risks associated with EACMSs, particularly those posed by compromise of electronic access functions, NERC staff recommends that the Supply Chain Standards be modified to include EACMSs that perform electronic access control for high and medium BES Cyber Systems.” 

The addition of EACMS that only perform logging and monitoring access to the Supply Chain Standards, especially CIP-005-6 R2.4 and R2.5, would likely cause additional operational costs and significant admirative burden on systems that both FERC and NERC have indicated are not of equal risk to the BPS as those systems that are performing access controls to an ESP.

Amy Casuscelli, On Behalf of: Xcel Energy, Inc. - MRO, WECC - Segments 1, 3, 5, 6

- 0 - 0

ISO/RTO Council Standards Review Committee 2019-03 Supply Chain Risks, Segment(s) 2, 3/11/2020

- 0 - 0

Westar Energy, an Evergy company, supports Edison Electric Institutes responses to Question 1.

Douglas Webb, 3/11/2020

- 0 - 0

Exelon will align with EEI's comments in response to this question.

Kinte Whitehead, Exelon, 3, 3/11/2020

- 0 - 0

PUD No. 1 of Chelan County , Segment(s) 1, 3, 6, 3/11/2020

- 0 - 0

EEI supports the addition of EACMS and agrees that modifications to the supply chain standards to address EACMS and specifically controls for ensuring reliability and security as stated in FERC Order 850 at P47 is appropriate.  The Commission stated that “the standard drafting team that is formed in response to our present directive may determine…what EACMS functions are most important to the reliable operation of the Bulk-Power System and therefore should be included in the supply chain risk management Reliability Standard.” (Order 850 at P55)   We also note that in the NERC Cyber Security Supply Chain Risks Report dated May 17, 2019; it recommended only “revising the standard to include those systems that provide electronic access control (excluding monitoring and logging) to high and medium impact BES Cyber Systems.” (Chapter 2, Overview, P7)  Hence, the Commission has provided the Standards Drafting Team sufficient latitude, within FERC Order 850, to focus the scope of EACMS based on supporting analysis.   

Mark Gray, On Behalf of: Edison Electric Institute, NA - Not Applicable, Segments NA - Not Applicable

- 0 - 0

 

While we agree with the addition of EACMS to CIP-005, CIP-010 and CIP-013, we suggest that the SDT consider creating a new requirement, CIP-005-7 R3, and move Part 2.4 and Part 2.5 to this new requirement.  We believe that this will help to alleviate any confusion that may exist surrounding EACMS and Intermediate Systems.While we agree with the addition of EACMS to CIP-005, CIP-010 and CIP-013, we suggest that the SDT consider creating a new requirement, CIP-005-7 R3, and move Part 2.4 and Part 2.5 to this new requirement.  We believe that this will help to alleviate any confusion that may exist surrounding EACMS and Intermediate Systems.

Louisville Gas and Electric Company and Kentucky Utilities Company, Segment(s) 3, 5, 6, 9/6/2018

- 0 - 0

MidAmerican agrees with MRO NSRF comments.

Darnez Gresham, Berkshire Hathaway Energy - MidAmerican Energy Co., 3, 3/11/2020

- 0 - 0

Overall, Southern DOES NOT agree with the addition of EACMS as it has been proposed in these draft Standards as it does not align with the requirement from FERC Order 850.  The SDT needs to address the scenario of terminating vendor remote access to the (EACMS) assets that are used to allow and prevent vendor remote access.  In essence, if I must only allow vendor remote access through an authorized and authenticated session at an EACMS, and that EACMS is the asset I would use to prevent vendor remote access to a BCS, how then can I also prevent vendor remote access to that very asset that I use to terminate that remote access?  This results in illogical loop.  Also consider how to handle situations where a vendor is managing EACMS on behalf of the entity where disabling access to access controls seems causes that type of an illogical loop. 


FERC has not ordered adding EACMS requirements to exactly the same requirements that apply to BCS as part of this Supply Chain initiative by merely changing the Applicable Systems column.  There could be less restrictive requirements or new requirements based on risk that could apply to EACMS. We agree with the FERC Order that there should be additional requirements for those EACS assets that perform “access control” functions and not merely monitoring and logging functions. Given the absence of an attempt to modify the NERC defined term for EACMS to clarify the difference between EACS and EAMS, we do not agree with the addition of EACMS at this time as the current definition of EACMS assets to which these new requirements would apply is above and beyond the scope addressed in the FERC Order and the NERC Final Report.

For these reasons, keeping requirements applicable to EACMS in CIP-010 and CIP-013 addresses the FERC Order, however Southern believes the SDT should remove EACMS from CIP-005 R2.4 and R2.5 until such time that the EACMS definition can be modified and new definitions of applicable systems be added to properly scope these requirements, and the SDT can address the infinite loop issues addressed above.

 

Southern Company, Segment(s) 1, 3, 5, 6, 12/13/2019

- 0 - 0

We agree conceptually with including EACMS but need to assess the risk and implementation.

We agree conceptually on the intent but we think that there is a need to better define the requirements. The added requirements are in the IRA section of CIP-005 R2, one could think that for accessing the EACMS an Intermediate system is required.

RSC, Segment(s) 10, 2, 4, 5, 7, 3, 1, 6, 3/11/2020

- 0 - 0

Mark Ciufo, On Behalf of: Payam Farahbakhsh, Hydro One Networks, Inc., 1,3

- 0 - 0

Eversource Group, Segment(s) 3, 1, 4/12/2019

- 0 - 0

Jeff Icke, Colorado Springs Utilities, 5, 3/11/2020

- 0 - 0

Rachel Coyne, Texas Reliability Entity, Inc., 10, 3/11/2020

- 0 - 0

Tampa Electric supports EEI comments which supports the addition of EACMS and agrees that modifications to the supply chain standards to address EACMS and specifically controls for ensuring reliability and security as stated in FERC  Order 850 at P47 is appropriate. The Commission stated that “the standard drafting team that is formed in response to our present directive may determine…what EACMS functions are most important to the reliable operation of the Bulk-Power System and therefore should be included in the supply chain risk management Reliability Standard.” (Order 850 at P55)  We also note that in the NERC Cyber Security Supply Chain Risks Report dated May 17, 2019; it recommended only “revising the standard to include those systems that provide electronic access control (excluding monitoring and logging) to high and medium impact BES Cyber Systems.” (Chapter 2, Overview,  P7) Hence, the Commission has provided the Standards Drafting Team sufficient latitude, within FERC Order 850, to focus the scope of EACMS based on supporting analysis.

Ronald Donahey, TECO - Tampa Electric Co., 3, 3/11/2020

- 0 - 0

CIP-005 is not currently applicable to EACMS and PACS, along with items such as Electronic Security Perimeters, Electronic Access Points, and Interactive Remote Access. The proposed changes to CIP-005 R2.4 and R2.5 bring Interactive Remote Access applicability to EACMS / PACS. There should be clarity and differentiation between Interactive Remote Access for BES Cyber Systems / Protected Cyber Assets and vendor remote access for EACMS / PACS. Interactive Remote Access has additional controls, such as multi-factor authentication. The proposed changes can cause confusion on the applicability of Interactive Remote Access and other CIP-005 controls to EACMS and PACS.

LCRA Compliance, Segment(s) 6, 5, 1, 5/11/2015

- 0 - 0

Maryanne Darling-Reich, On Behalf of: Black Hills Corporation, MRO, WECC, Segments 1, 3, 5, 6

- 0 - 0

Jesus Sammy Alcaraz, Imperial Irrigation District, 1, 3/11/2020

- 0 - 0

While the addition of PACS and EACMS may appear to meet the spirit of the FERC Order, the addition of these two device types to CIP-005 R2 Parts 2.4 and 2.5 poses a challenge. Interactive Remote Access relies on the presence of an Electronic Security Perimeter or an Electronic Access Point, neither of which is a requirement that applies to PACS or EACMS. In its current form, the addition of PACS and EACMS to CIP-005 R2 Parts 2.4 & 2.5 would only apply to system-to-system vendor remote access, and not vendor interactive remote access. There is more work to be done to include the intended target of IRA when adding PACS and EAMCS to the applicability column.

 

Suggest either update the definition of IRA or remove the capitalization from the IRA term in requirement language of CIP-005 R2 Parts 2.4 & 2.5.

Marc Donaldson, Tacoma Public Utilities (Tacoma, WA), 3, 3/11/2020

- 0 - 0

Support the MRO comments.

Wayne Guttormson, SaskPower, 1, 3/11/2020

- 0 - 0

Hot Answers

MidAmerican agrees with MRO NSRF comments.

Terry Harbour, On Behalf of: Berkshire Hathaway Energy - MidAmerican Energy Co., , Segments 1, 3

- 0 - 0

Please see comments submitted by Edison Electric Institute.

Kenya Streeter, Edison International - Southern California Edison Company, 6, 3/11/2020

- 0 - 0

Other Answers

Kevin Conway, Public Utility District No. 1 of Pend Oreille County, 1, 1/28/2020

- 0 - 0

Tho Tran, 2/26/2020

- 0 - 0

Kelsi Rigby, 2/27/2020

- 0 - 0

Tim Womack, 3/2/2020

- 0 - 0

LaTroy Brumfield, American Transmission Company, LLC, 1, 3/2/2020

- 0 - 0

The NERC Cyber Security Supply Chain Risks white paper recommendations excludes a) EACMS which provide monitoring and logging and b) PACS which perform alarming and logging  services. The applicability and definitions in the revisions  do not distinguish between preventive (firewalls) and detective (monitoring/alarming/logging) EACMS and PACS. In addition, the Applicable Systems and language does not distinguish between EACMS and PACS with ERC. Recommend revising Definitions, Applicable Systems and Parts to address only EAMCS and PACS with ERC and which perform preventive security services.

CIP-010-4  – Applicable Systems – PACS (pp5-6): current term of a PACS  “except as provided in Requirement R1, Part 1.6.” adds Cyber Systems into scope which are not in scope. It is not clear and confusing.

CIP-010-4 R1.6 – does not distinguish BCS with ERC from BCS without – in context, adds Cyber Systems to this requirement which are not in scope for the FERC Order 850 or NERC Cyber Security Supply Chain Risks white paper

sean erickson, Western Area Power Administration, 1, 3/2/2020

- 1 - 0

NO.  Adding PACS is not necessary.  The Standards as they are right now are just fine.

Marty Hostler, Northern California Power Agency, 4, 3/2/2020

- 0 - 0

Adding PACS is not necessary.  The standards as they are right now are just fine.

Dennis Sismaet, Northern California Power Agency, 6, 3/3/2020

- 0 - 0

Adding PACs is not necessary.  The standards as they are right now are just fine.

Scott Tomashefsky, 3/3/2020

- 0 - 0

We agree to add PACS to the applicable systems but disagree with the language regarding PACS in CIP-013-2 R1 and CIP-010-4 Section 6 Background since it would bring PACS associated with BCS w/o ERC into scope. Currently It has been commonly understood that only PACS associated with BCS with ERC is applicable to the CIP standards based on CIP-006 R1.1 requirement in which PACS is not required for medium impact BCS without ERC. We suggest making the following changes:

For CIP-013-2 R1, Part 1.1 and Part 1.2, change “high and medium impact BES Cyber Systems and their associated EACMS and PACS” to “high and medium impact BES Cyber Systems and their associated EACMS, and PACS associated with high impact BES Cyber Systems or medium impact BES Cyber Systems with External Routable Connectivity.”

For CIP-010-4, remove the wording “except as provided in Requirement R1, Part 1.6.” from Section 6 Background.

Bruce Reimer, 3/5/2020

- 0 - 0

Duke Energy generally agrees with adding PACS to the Supply Chain Standards as currently described above.

Duke Energy, Segment(s) 1, 5, 6, 3, 12/13/2019

- 0 - 0

We agree with the addition of PACS (and EACMS) to CIP-005-7 and CIP-013-2, but a close examination of the currently approved definition(s) of PACS (and EACMS) prevents them from being added to Medium Impact BES Cyber Systems in CIP-010-4 Requirement R1, Part 1.6 as proposed.

PACS are currently defined as:

“Cyber Assets that control, alert, or log access to the Physical Security Perimeter(s), exclusive of locally mounted hardware or devices at the Physical Security Perimeter such as motion sensors, electronic lock control mechanisms, and badge readers.”

PACS are tied to PSPs. PSPs only exist with respect to Medium Impact BES Cyber Systems for those with ERC per CIP-006-6 Requirement R1, Part 1.2. Medium Impact BES Cyber Systems without External Routable Connectivity are only required to define operational or procedural controls to restrict physical access; a PACS is not required.

We recommend, for clarity and consistency among CIP standards:

1.) Insert:

“Medium Impact BES Cyber Systems with External Routable Connectivity and their associated:

1.  EACMS; and

2.  PACS”

Between High Impact and Medium Impact Applicable Systems in CIP-010-4 Requirement R1, Part 1.6.

2.) Delete “except as provided in Requirement R1, Part 1.6” from the PACS description in the Background on p. 6.

Although the PACS applicability language does not directly affect CIP-005-7, we recommend that the new inclusion of PACS applicability in the Background on p. 6 include “with External Routable Connectivity” to be consistent with most of the standards.  CIP-006-6 and CIP-007-6 should likewise be corrected during the next revision.

CIP-006-6 and CIP-007-6 language:

“Physical Access Control Systems (PACS) – Applies to each Physical Access Control System associated with a referenced high impact BES Cyber System or medium impact BES Cyber System.”

CIP-004-6, CIP-009-6, CIP-010-3 and CIP-011-2 language:

“Physical Access Control Systems (PACS) – Applies to each Physical Access Control System associated with a referenced high impact BES Cyber System or medium impact BES Cyber System with External Routable Connectivity.”

Also, in keeping with the same principle, for CIP-013-2, we suggest changing Requirement R1, “for high and medium impact BES Cyber Systems and their associated EACMS and PACS,” to “for high and medium impact BES Cyber Systems, and EACMS and PACS associated with high impact BES Cyber Systems or medium impact BES Cyber Systems with External Routable Connectivity.”

Dana Klem, On Behalf of: MRO - MRO - Segments 1, 2, 3, 4, 5, 6

- 1 - 0

Anthony Jablonski, ReliabilityFirst , 10, 3/6/2020

- 0 - 0

GSOC and GTC do not agree with or support the addition of PACS to the applicable systems for the supply chain reliability standards.  In particular, GSOC and GTC are concerned regarding NERC’s conclusion in Chapter 3 of the Supply Chain Risks report that “…if compromised, misused, or rendered unavailable, PACS components could have a real-time impact on the reliability of the BES” because the conclusion is inconsistent with the current classification of PACS components in a category distinct from BES Cyber Assets, and because a compromise of a PACS would not have a real-time impact on the BES without a secondary action.

In accordance with the typical implementation of reliability standard CIP-002-5.1a and pursuant to the NERC-approved definition, if a cyber asset has or could have a direct impact on the reliability of the BES, it must be characterized as a BES Cyber Asset.  A BES Cyber Asset is defined “[a] Cyber Asset that if rendered unavailable, degraded, or misused would, within 15 minutes of its required operation, misoperation, or non-operation, adversely impact one or more Facilities, systems, or equipment, which, if destroyed, degraded, or otherwise rendered unavailable when needed, would affect the reliable operation of the Bulk Electric System.  Redundancy of affected Facilities, systems, and equipment shall not be considered when determining adverse impact. Each BES Cyber Asset is included in one or more BES Cyber Systems.”  Importantly, cyber assets that are classified as PACS are classified as such because they perform unique functions required by the CIP reliability standards, including, but not limited to CIP-006, CIP-004, etc.  Hence, where responsible entities identify cyber assets that “…. control, alert, or log access to the Physical Security Perimeter(s), exclusive of locally mounted hardware or devices at the Physical Security Perimeter such as motion sensors, electronic lock control mechanisms, and badge readers,” such cyber assets are appropriately classified as PACS.   Thus, it is difficult to reach the same conclusion as NERC and the SDT, e.g., that a compromise, misuse, or rendering unavailability to PACS components would directly affect the reliable operation of the BES. 

More importantly, though, these definitions form the foundation of cyber asset classification and the overall industry interpretation of how its cyber assets should be classified.  The assertion by NERC that PACS directly impact the reliability of the BES and the SDT’s acceptance of this to justify their inclusion in the applicability for the supply chain reliability standards effectively upends nearly a decade of Commission, ERO, and industry precedent regarding what constitutes a BES Cyber Asset and what constitutes supporting cyber assets such as PACS. 

GSOC and GTC acknowledge that the compromise, misuse, or rendering unavailable of PACS could be an initiating action for a secondary action of compromise, misuse, or rendering unavailable of a BES Cyber Asset or other cyber asset when determining adverse impact to the reliability of the BES.  However, the singular, isolated cyber compromise to PACS without other secondary action does not and would not have real-time impacts on the reliability of the BES.  More specifically, without a concurrent or subsequent physical compromise, the compromise, misuse, or rendering unavailable of a PACS alone cannot have a direct impact on the reliability of the BES.  A second order of physical presence by way of entry into the Physical Security Perimeter must occur to impact reliability. 

The inclusion of secondary actions when determining direct impacts is atypical generally and is also inapposite to the risk-based nature of the CIP reliability standards, the BES Cyber Asset definition, and the significance of asset redundancy as a risk mitigating strategy.   The need for a secondary action (physical security compromise) and – potentially- a tertiary action (e.g., the compromise, misuse, or rendering unavailable of a BES Cyber Asset or BES asset equipment) clearly demonstrates that adverse action to PACS alone cannot directly impact the reliability of the BES.  Given this reality, PACS would not and should not (in the CIP reliability standards risk based framework) require the same protections as those cyber assets that could directly impact the reliability of the BES. 

NERC correctly refers to various Reliability Standards that mitigate security risks relating to PACS.  These include CIP-004-6; CIP-006-6; CIP-007-6; CIP-009-6; CIP-010-2; and CIP-011-2. GSOC and GTC assert that these protections are sufficient given the attenuated relationship that a PACS compromise has to BES reliability impacts.  For these reasons, GSOC and GTC oppose the inclusion/addition of PACS to the supply chain reliability standards.  While GSOC and GTC understand the potential risks identified by NERC in Chapter 3 of its Supply Chain Risks report, they believe that these risks are already appropriately mitigated through the protections that are mandated for PACS within the existing set of CIP reliability standards.

Andrea Barclay, 3/6/2020

- 0 - 0

OPG supports RSC comments.

Constantin Chitescu, Ontario Power Generation Inc., 5, 3/6/2020

- 0 - 0

Andrea Jessup, On Behalf of: Bonneville Power Administration, WECC, Segments 1, 3, 5, 6

- 0 - 0

Jennifer Wright, Sempra - San Diego Gas and Electric, 5, 3/6/2020

- 0 - 0

David Reinecke, On Behalf of: Seminole Electric Cooperative, Inc., , Segments 1, 3, 4, 5, 6

- 0 - 0

We agree conceptually with including PACS but need to assess the risk and implementation. However, we expect a lower return on investment on PACS.

There should be some awareness message on the change for CIP-010-4 R1.6 on third party or shared infrastructure.

Was it intentional to not capitalize electronic access point in CIP-005 R2.5 bullet three of the measures?

Leonard Kula, On Behalf of: Independent Electricity System Operator, , Segments 2

- 0 - 0

FE Voter, Segment(s) 1, 3, 5, 6, 4, 10/31/2019

- 0 - 0

PG&E agrees with the addition of PACS but does not agree with the use of PACS as currently defined in the “Applicable System Columns in Tables” section of the Standard.  Including PACS which only provide monitoring or alerting capabilities in the modifications extends what was indicated in the NERC supply chain study recommendation which indicated only “access control” capabilities.  PG&E believes the risk of PACS which “only” provides monitoring and alerting capabilities is not the same as those which provide “access control” capabilities and should be excluded from the Standard.  PG&E does indicate if a PACS provides access control while at the same time monitoring and/or alerting capabilities it should be covered by the Standard.

 

PG&E recommends the definition in the “Applicable System Columns in Tables” section be altered to indicate only those PACS which provide “access control” and that PACS that only provide monitoring and alerting be excluded.  A Technical Rationale document could be created to clearly indicate what type of PACS would be covered with examples to help clarify any confusion.  A potential benefit in making the “Applicable Systems Column in Table” indicate PACS with only “access control” is to the Project 2016-02 SDT working on the separation of PACS into Cyber Assets for “access control” (PACS) and monitoring/alerting (PAMS).  A clear indication of “access control” in the Project 2019-03 modifications could make it easier for the Project 2016.-02 SDT to make conforming changes to CIP-005, CIP-010, and CIP-013 once they are ready to complete the work on the PACS separation.

 

PG&E All Segments, Segment(s) 1, 3, 5, 2/10/2020

- 0 - 0

Anton Vu, Los Angeles Department of Water and Power, 6, 3/9/2020

- 0 - 0

Eli Rivera, On Behalf of: CenterPoint Energy Houston Electric, LLC, Texas RE, Segments NA - Not Applicable

- 0 - 0

Alliant Energy does not oppose the addition of PACS, but agrees with the NSRF that consideration and clarity is needed around Medium Impact BES Cyber Systems with and without External Routable Connectivity.

Jenifer Holmes, On Behalf of: Alliant Energy Corporation Services, Inc. - MRO, RF - Segments 4

- 0 - 0

Exelon is aligning with EEI's comments for this question.

Daniel Gacek, Exelon, 1, 3/9/2020

- 0 - 0

Please see comments submitted by Edison Electric Institute

Ayman Samaan, 3/9/2020

- 0 - 0

ISO-NE agrees conceptually with including PACS but needs to assess the risk and implementation. However, we expect a lower return on investment on PACS.

There should be some awareness message on the change for CIP-010-4 R1.6 on third party or shared infrastructure.

Was it intentional to not capitalize electronic access point in CIP-005 R2.5 bullet three of the measures?

We agree with the proposed changes. We do see one issue with the change to the applicability of PACS on page 6 of the redlined standard document for CIP-010-4.  We question whether the exception should be added or maybe it needs to also include part 1.1.  I’m not sure it makes sense to include additional devices in part 1.6 that are not included in 1.1 given that 1.6 must be followed only when there is a change to the baseline defined in 1.1

John Galloway, On Behalf of: Michael Puscas, ISO New England, Inc., 2

- 0 - 0

Dania Colon, Orlando Utilities Commission, 5, 3/10/2020

- 0 - 0

ACES Standard Collaborations, Segment(s) 1, 3, 4, 5, 3/10/2020

- 0 - 0

1. The NERC Cyber Security Supply Chain Risks white paper recommendations excludes a) EACMS which provide monitoring and logging and b) PACS which perform alarming and logging services. The applicability and definitions in the revisions do not distinguish between preventive (firewalls) and detective (monitoring/alarming/logging) EACMS and PACS. This leads to confusion when identifying and developing procedures for cyber assets in or out of scope, when determining compliance to the standard, and at audits or when processing risk, cause, corrective and enforcement actions.

Recommend either removing the references in all revisions or revise the SAR to include a separate class of Cyber Systems which perform either the preventive control (IPS, Firewalls) or detective control functions (IDS, logging and alerting)

2. The “Applicable Systems” language does not distinguish between medium EACMS and PACS with ERC, however ERC is a consideration when classifying systems in the Parts.

Recommend initiating a revision to the Applicable Systems and Parts to address only a) EACMS and PACS with ERC as follows:

"Physical Access Control Systems (PACS) with External Routable Connectivity – Applies to each Physical Access Control System with ERC and associated with a referenced high impact or medium impact BES Cyber System"

"Electronic Access Control or Monitoring Systems (EACMS) with External Routable Connectivity – Applies to each Electronic Access Control or Monitoring System with ERC and associated with a referenced high or medium impact BES Cyber System. Examples may include, but are not limited to, firewalls, authentication servers, and log monitoring and alerting systems."

3. CIP-010-4  – “Applicable Systems” – PACS (pp5-6) includes for PACS  “except as provided in Requirement R1, Part 1.6.” This is confusing and potentially adds Cyber Systems into scope which are not in scope

Recommend updating the Applicable Systems definitions to match the Parts where ERC is or is not required.

4. CIP-010-4 Part R1.6 – does not distinguish BCS with ERC from BCS without – in context, adds Cyber Systems to this requirement which are not in scope for the FERC Order 850 or NERC Cyber Security Supply Chain Risks white paper

 

Barry Jones, On Behalf of: Rosemary Jones, Western Area Power Administration, 1,6

- 0 - 0

Dmitriy Bazylyuk, 3/10/2020

- 0 - 0

Jamie Prater, 3/10/2020

- 0 - 0

We agree conceptually on the intent but wonder if there is a real benefits on the overall electric reliability.

Nicolas Turcotte, Hydro-Qu?bec TransEnergie, 1, 3/10/2020

- 0 - 0

Although the CAISO acknowledges that PACS are as important to protect as the BCS in line with the FERC Order, we recommend to wait on wait with extending the program to PACS until after the upcoming CIP-005-6, CIP-010-3 and CIP-013-1 standards have been in effect for at least a two years to allow for the processes and controls to mature, to obtain any key learnings from implementing these protections and from audit experiences including findings and areas of concerns identified by the  auditors. At that time the CAISO also proposes NERC issue a CIP-013-1 survey amongst the industry to collect recommendations for improvement of the industry’s supply chain security standard.

Monika Montez, On Behalf of: California ISO, WECC, Segments 2

- 0 - 0

It’s not clear what risk this is mitigating.  Critical sites have additional protections (security guards) that are in place and will continue to provide visibility where needed in the event someone obtains unauthorized remote access to PACS.

Joshua Andersen, On Behalf of: Salt River Project, WECC, Segments 1, 3, 5, 6

- 0 - 0

Richard Jackson, U.S. Bureau of Reclamation, 1, 3/10/2020

- 0 - 0

Roger Fradenburgh, On Behalf of: Nicholas Lauriat, Network and Security Technologies, 1

- 0 - 0

Andy Fuhrman, On Behalf of: Theresa Allard, Minnkota Power Cooperative Inc., 1

- 0 - 0

Carl Pineault, Hydro-Qu?bec Production, 5, 3/11/2020

- 0 - 0

Ameren agrees with and supports EEI comments.

David Jendras, Ameren - Ameren Services, 3, 3/11/2020

- 0 - 0

Glen Farmer, Avista - Avista Corporation, 5, 3/11/2020

- 0 - 0

GSOC and GTC do not agree with or support the addition of PACS to the applicable systems for the supply chain reliability standards.  In particular, GSOC and GTC are concerned regarding NERC’s conclusion in Chapter 3 of the Supply Chain Risks report that “…if compromised, misused, or rendered unavailable, PACS components could have a real-time impact on the reliability of the BES” because the conclusion is inconsistent with the current classification of PACS components in a category distinct from BES Cyber Assets, and because a compromise of a PACS would not have a real-time impact on the BES without a secondary action.

 

In accordance with the typical implementation of reliability standard CIP-002-5.1a and pursuant to the NERC-approved definition, if a cyber asset has or could have a direct impact on the reliability of the BES, it must be characterized as a BES Cyber Asset.  A BES Cyber Asset is defined “[a] Cyber Asset that if rendered unavailable, degraded, or misused would, within 15 minutes of its required operation, misoperation, or non-operation, adversely impact one or more Facilities, systems, or equipment, which, if destroyed, degraded, or otherwise rendered unavailable when needed, would affect the reliable operation of the Bulk Electric System.  Redundancy of affected Facilities, systems, and equipment shall not be considered when determining adverse impact. Each BES Cyber Asset is included in one or more BES Cyber Systems.”  Importantly, cyber assets that are classified as PACS are classified as such because they perform unique functions required by the CIP reliability standards, including, but not limited to CIP-006, CIP-004, etc.  Hence, where responsible entities identify cyber assets that “…. control, alert, or log access to the Physical Security Perimeter(s), exclusive of locally mounted hardware or devices at the Physical Security Perimeter such as motion sensors, electronic lock control mechanisms, and badge readers,” such cyber assets are appropriately classified as PACS.   Thus, it is difficult to reach the same conclusion as NERC and the SDT, e.g., that a compromise, misuse, or rendering unavailability to PACS components would directly affect the reliable operation of the BES. 

 

More importantly, though, these definitions form the foundation of cyber asset classification and the overall industry interpretation of how its cyber assets should be classified.  The assertion by NERC that PACS directly impact the reliability of the BES and the SDT’s acceptance of this to justify their inclusion in the applicability for the supply chain reliability standards effectively upends nearly a decade of Commission, ERO, and industry precedent regarding what constitutes a BES Cyber Asset and what constitutes supporting cyber assets such as PACS. 

 

GSOC and GTC acknowledge that the compromise, misuse, or rendering unavailable of PACS could be an initiating action for a secondary action of compromise, misuse, or rendering unavailable of a BES Cyber Asset or other cyber asset when determining adverse impact to the reliability of the BES.  However, the singular, isolated cyber compromise to PACS without other secondary action does not and would not have real-time impacts on the reliability of the BES.  More specifically, without a concurrent or subsequent physical compromise, the compromise, misuse, or rendering unavailable of a PACS alone cannot have a direct impact on the reliability of the BES.  A second order of physical presence by way of entry into the Physical Security Perimeter must occur to impact reliability. 

 

The inclusion of secondary actions when determining direct impacts is atypical generally and is also inapposite to the risk-based nature of the CIP reliability standards, the BES Cyber Asset definition, and the significance of asset redundancy as a risk mitigating strategy.   The need for a secondary action (physical security compromise) and – potentially- a tertiary action (e.g., the compromise, misuse, or rendering unavailable of a BES Cyber Asset or BES asset equipment) clearly demonstrates that adverse action to PACS alone cannot directly impact the reliability of the BES.  Given this reality, PACS would not and should not (in the CIP reliability standards risk based framework) require the same protections as those cyber assets that could directly impact the reliability of the BES. 

 

NERC correctly refers to various Reliability Standards that mitigate security risks relating to PACS.  These include CIP-004-6; CIP-006-6; CIP-007-6; CIP-009-6; CIP-010-2; and CIP-011-2. GSOC and GTC assert that these protections are sufficient given the attenuated relationship that a PACS compromise has to BES reliability impacts.  For these reasons, GSOC and GTC oppose the inclusion/addition of PACS to the supply chain reliability standards.  While GSOC and GTC understand the potential risks identified by NERC in Chapter 3 of its Supply Chain Risks report, they believe that these risks are already appropriately mitigated through the protections that are mandated for PACS within the existing set of CIP reliability standards. 

Greg Davis, On Behalf of: Georgia Transmission Corporation, , Segments 1

- 0 - 0

Exelon has aligned with EEI's comment in response to this question.

Cynthia Lee, Exelon, 5, 3/11/2020

- 0 - 0

Exelon will align with EEI's comments in response to this question.

Becky Webb, Exelon, 6, 3/11/2020

- 0 - 0

Xcel Energy supports EEI comments and does not oppose the addition of PACS.

Amy Casuscelli, On Behalf of: Xcel Energy, Inc. - MRO, WECC - Segments 1, 3, 5, 6

- 0 - 0

The IRC SRC requests clarification. Was it the SDT’s intent not to capitalize “electronic access point” and “intermediate system” under CIP-005-7, requirement R2, part 2.5, bullet three under Measures?

NYISO doesn’t understand the applicability for controls for remote access regarding PACS devices as implied within CIP-005 remote access requirements.

ISO/RTO Council Standards Review Committee 2019-03 Supply Chain Risks, Segment(s) 2, 3/11/2020

- 0 - 0

Westar Energy, an Evergy company, supports Edison Electric Institutes responses to Question 2.

Douglas Webb, 3/11/2020

- 0 - 0

Exelon will align with EEI's comments in response to this question.

Kinte Whitehead, Exelon, 3, 3/11/2020

- 0 - 0

CHPD believes that the PACS should not be added per the following discussion.

The Cyber Security Supply Chain Risks Staff Report and Recommended Actions (May 17, 2019) recommended that PCAs be excluded from CIP-013-2 because 1) the risk is difficult to quantify and 2) there is not a direct 15-minute impact related to the PCA itself.  The PCAs were excluded from CIP-010 and CIP-013, but included a recommendation to address them as a best practice.

PCAs, like PACS, have no direct 15-minute BES impact.  PACS, unlike PCAs, do not reside within an ESP and have no network access to the BCS or related ESP.  Therefore; if PCAs are not included, it seems logical for PACS to be treated in the same manner.

The NERC Cyber Security Supply Chain Risks Staff Report and Recommended Actions (May 17, 2019) reasoned that PCA could be excluded from CIP-010 and CIP-013 due to the following:

  1. “The potential risk can be mitigated in part by technical controls, some of which are addressed in the CIP Reliability Standards and others which can be addressed in policies and procedures. For example, implementing access control lists, intrusion prevention systems, and malicious software prevention tools can be used to limit the risk posed by PCAs possibly impacting interconnected BES Cyber Systems” (p. 21).

  2. The recommendation was to not include PCAs as “other controls deployed on the BES Cyber Systems under the CIP-007 and CIP-010 standards would protect the actual assets that could have a 15-minute impact if rendered unavailable, degraded, or misused” (p. 22).

In conclusion, CHPD agrees with the Cyber Security Supply Chain Risks Staff Report and Recommended Actions (May 17, 2019) recommendation to exclude PCAs in favor of a best practice approach and adequate cyber security controls.  CHPD recommends that this same reasoning be extended to PACS due to the lower potential risk to the BES.

 

PUD No. 1 of Chelan County , Segment(s) 1, 3, 6, 3/11/2020

- 0 - 0

EEI does not oppose the addition of PACS.

Mark Gray, On Behalf of: Edison Electric Institute, NA - Not Applicable, Segments NA - Not Applicable

- 0 - 0

While we agree with the addition of PACS to CIP-005, CIP-010 and CIP-013, we suggest that the SDT consider creating a new requirement, CIP-005-7 R3, and move Part 2.4 and Part 2.5 to this new requirement.  We believe that this will help to alleviate any confusion that may exist surrounding PACS and Intermediate Systems.

Louisville Gas and Electric Company and Kentucky Utilities Company, Segment(s) 3, 5, 6, 9/6/2018

- 0 - 0

MidAmerican agrees with MRO NSRF comments.

Darnez Gresham, Berkshire Hathaway Energy - MidAmerican Energy Co., 3, 3/11/2020

- 0 - 0

Southern DOES NOT agree with the addition of PACS as it has been proposed in these draft Standards as it does not align with the requirement from FERC Order 850.  The SDTs has now inadvertently brought into scope corporate systems and applications that do not meet the defined terms of an Applicable System.  Since PACS are not required to be in an ESP, and remote access to them is not required to traverse through an Intermediate System, then there is no existing outer boundary used for remote access to PACS assets that is in-scope.  FERC has not ordered adding PACS requirements to exactly the same requirements that apply to BCS as part of this Supply Chain initiative by merely changing the Applicable Systems column.  There could be less restrictive requirements or new requirements based on risk that could apply to PACS. We agree with the FERC Order and the NERC Study that there should be additional requirements for those PACS assets that perform “access control” functions and not merely monitoring and logging functions. Given the absence of an attempt to modify the NERC defined term for PACS to clarify the difference between PACS and PAMS, we do not agree with the addition of PACS at this time as the current definition of PACS assets to which these new requirements would apply is above and beyond the scope addressed in the FERC Order and the NERC Final Report.

For these reasons, keeping requirements applicable to PACS in CIP-010 and CIP-013 addresses the FERC Order and NERC Study, however Southern believes the SDT should remove PACS from CIP-005 R2.4 and R2.5 until such time that the PACS definition can be modified and new definitions of applicable systems be added to properly scope these requirements.

Southern Company, Segment(s) 1, 3, 5, 6, 12/13/2019

- 0 - 0

We agree conceptually with including PACS but need to assess the risk and implementation. However, we expect a lower return on investment on PACS.

 

There should be some awareness message on the change for CIP-010-4 R1.6 on third party or shared infrastructure.

 

Was it intentional to not capitalize electronic access point in CIP-005 R2.5 bullet three of the measures?

 

Another issue with the change to the applicability of PACS on page 6 of the redlined standard document for CIP-010-4.  We question whether the exception should be added or maybe it needs to also include part 1.1.  I’m not sure it makes sense to include additional devices in part 1.6 that are not included in 1.1 given that 1.6 must be followed only when there is a change to the baseline defined in 1.1.

RSC, Segment(s) 10, 2, 4, 5, 7, 3, 1, 6, 3/11/2020

- 0 - 0

Mark Ciufo, On Behalf of: Payam Farahbakhsh, Hydro One Networks, Inc., 1,3

- 0 - 0

Eversource Group, Segment(s) 3, 1, 4/12/2019

- 0 - 0

Jeff Icke, Colorado Springs Utilities, 5, 3/11/2020

- 0 - 0

Rachel Coyne, Texas Reliability Entity, Inc., 10, 3/11/2020

- 0 - 0

Tampa Elecric does not oppose the addition of PACS.

Ronald Donahey, TECO - Tampa Electric Co., 3, 3/11/2020

- 0 - 0

CIP-005 is not currently applicable to EACMS and PACS, along with items such as Electronic Security Perimeters, Electronic Access Points, and Interactive Remote Access. The proposed changes to CIP-005 R2.4 and R2.5 bring Interactive Remote Access applicability to EACMS / PACS. There should be clarity and differentiation between Interactive Remote Access for BES Cyber Systems / Protected Cyber Assets and vendor remote access for EACMS / PACS. Interactive Remote Access has additional controls, such as multi-factor authentication. The proposed changes can cause confusion on the applicability of Interactive Remote Access and other CIP-005 controls to EACMS and PACS.

LCRA Compliance, Segment(s) 6, 5, 1, 5/11/2015

- 0 - 0

Maryanne Darling-Reich, On Behalf of: Black Hills Corporation, MRO, WECC, Segments 1, 3, 5, 6

- 0 - 0

Jesus Sammy Alcaraz, Imperial Irrigation District, 1, 3/11/2020

- 0 - 0

While the addition of PACS and EACMS may appear to meet the spirit of the FERC Order, the addition of these two device types to CIP-005 R2 Parts 2.4 and 2.5 poses a challenge. Interactive Remote Access relies on the presence of an Electronic Security Perimeter or an Electronic Access Point, neither of which is a requirement that applies to PACS or EACMS. In its current form, the addition of PACS and EACMS to CIP-005 R2 Parts 2.4 & 2.5 would only apply to system-to-system vendor remote access, and not vendor interactive remote access. There is more work to be done to include the intended target of IRA when adding PACS and EAMCS to the applicability column.

 

Suggest either update the definition of IRA or remove the capitalization from the IRA term in requirement language of CIP-005 R2 Parts 2.4 & 2.5.

Marc Donaldson, Tacoma Public Utilities (Tacoma, WA), 3, 3/11/2020

- 0 - 0

Wayne Guttormson, SaskPower, 1, 3/11/2020

- 0 - 0

Hot Answers

MidAmerican agrees with MRO NSRF comments.

Terry Harbour, On Behalf of: Berkshire Hathaway Energy - MidAmerican Energy Co., , Segments 1, 3

- 0 - 0

Please see comments submitted by Edison Electric Institute.

Kenya Streeter, Edison International - Southern California Edison Company, 6, 3/11/2020

- 0 - 0

Other Answers

Kevin Conway, Public Utility District No. 1 of Pend Oreille County, 1, 1/28/2020

- 0 - 0

Tho Tran, 2/26/2020

- 0 - 0

Kelsi Rigby, 2/27/2020

- 0 - 0

Tim Womack, 3/2/2020

- 0 - 0

LaTroy Brumfield, American Transmission Company, LLC, 1, 3/2/2020

- 0 - 0

sean erickson, Western Area Power Administration, 1, 3/2/2020

- 0 - 0

NO.  They should be low, or better yet not a violation at all. 

Marty Hostler, Northern California Power Agency, 4, 3/2/2020

- 1 - 0

They should be low, or better yet not a violation at all.

Dennis Sismaet, Northern California Power Agency, 6, 3/3/2020

- 1 - 0

They should be low, or better yet not a violation at all.

Scott Tomashefsky, 3/3/2020

- 0 - 0

Bruce Reimer, 3/5/2020

- 0 - 0

Since PACS poses a lower risk to the BES, Duke Energy suggests that the VSLs should be lowered and should be no higher than Low or Moderate.

Duke Energy, Segment(s) 1, 5, 6, 3, 12/13/2019

- 0 - 0

We agree with the modified VSLs, but believe there are underlying problems with CIP-005-7 R2.4 and R2.5 as currently proposed.

1.) The requirements assume vendor remote access sessions and impose additional monitoring requirements upon all Responsible Entities regardless of whether or not a Responsible Entity permits vendor remote access sessions. There is no need for this ongoing requirement if an entity decides not to permit vendor remote access sessions and has ensured that such sessions are either blocked or not able to be established.

We recommend R2.4 be changed to add the following, or equivalent language, before the parenthesis:

“… where permitted and not otherwise blocked or unable to be established…”

R2.5 can then be changed to add “according to R2.4 above” before the parenthesis.

2.) Per the Background Information provided at the beginning of this comment form, we propose the following change to the Applicable Systems for R2.4 and R2.5 as a means of meeting the NERC supply chain report recommendations to include (i) EACMS that provide electronic access control (excluding monitoring and logging) (p. 7), and (ii) PACS that provide physical access control, excluding alerting and logging (p. 12) while retaining current definitions:

Expand EACMS to “EACMS that provide electronic access control (excluding monitoring and logging),” or equivalent language.

Expand PACS to “PACS that provide physical access control (excluding alerting and logging)”

Dana Klem, On Behalf of: MRO - MRO - Segments 1, 2, 3, 4, 5, 6

- 1 - 0

Anthony Jablonski, ReliabilityFirst , 10, 3/6/2020

- 0 - 0

While GSOC and GTC agree that the VSLs and VRFs associated with the addition of PACS should be lower, as discussed above, GSOC and GTC disagree with the addition of PACS to these requirements. 

Andrea Barclay, 3/6/2020

- 0 - 0

Constantin Chitescu, Ontario Power Generation Inc., 5, 3/6/2020

- 0 - 0

The wording is awkward and should be clarified to explain that failing to have one of the two methods required (determining OR disabling) is a moderate VSL while failure to have any of the required methods (lacking BOTH a means to determine and lacking a means to disable) is a high VSL.

Andrea Jessup, On Behalf of: Bonneville Power Administration, WECC, Segments 1, 3, 5, 6

- 0 - 0

Jennifer Wright, Sempra - San Diego Gas and Electric, 5, 3/6/2020

- 0 - 0

David Reinecke, On Behalf of: Seminole Electric Cooperative, Inc., , Segments 1, 3, 4, 5, 6

- 0 - 0

No Comments.

Leonard Kula, On Behalf of: Independent Electricity System Operator, , Segments 2

- 0 - 0

FE Voter, Segment(s) 1, 3, 5, 6, 4, 10/31/2019

- 0 - 0

PG&E agrees with the indicated VSL assignments for PACS.

PG&E All Segments, Segment(s) 1, 3, 5, 2/10/2020

- 0 - 0

Anton Vu, Los Angeles Department of Water and Power, 6, 3/9/2020

- 0 - 0

Eli Rivera, On Behalf of: CenterPoint Energy Houston Electric, LLC, Texas RE, Segments NA - Not Applicable

- 0 - 0

Alliant Energy agrees with the modified VSLs, but agrees with the NSRF that the language should be clarified for the scenario where a Responsible Entity does not permit vendor remote access sessions for some or all vendors.

Alliant Energy also supports the NSRF’s comments to update the applicability section to include only EACMS that provide electronic access control (excluding monitoring and logging) and PACS that provide physical access control (excluding alerting and logging).

Jenifer Holmes, On Behalf of: Alliant Energy Corporation Services, Inc. - MRO, RF - Segments 4

- 0 - 0

Exelon is aligning with EEI's comments for this question.

Daniel Gacek, Exelon, 1, 3/9/2020

- 0 - 0

Please see comments submitted by Edison Electric Institute

Ayman Samaan, 3/9/2020

- 0 - 0

ISO-NE disagrees with adding EACMS and PACS to CIP-005. CIP-005 was intended for access to High and PCA systems. In fact,

EACMs are derived from the CIP-005 requirements.

The CIP standards and requirements are structured to address security concerns based on the criticality and risk to the

BES. EACMS and PACS do not incur the same security concerns and do not have the same criticality or risk to the BES;

therefore, EACMS and especially PACS should not be treated the same as High or Medium Impact systems that have a

direct correlation to the reliability of the BES. Additionally, the co-mingled definition of “access control and monitoring”

inherently elevates systems with monitoring only capability to a high-water mark, adding the need to incorporate

burdensome and costly controls to extremely low risk systems for little benefit.

In support of the lower impact and risk, both VSLs should be listed as minimal to moderate.

John Galloway, On Behalf of: Michael Puscas, ISO New England, Inc., 2

- 0 - 0

Dania Colon, Orlando Utilities Commission, 5, 3/10/2020

- 0 - 0

Due to the low risks Vendor remote access to PACS have to the operation of the BES, we feel the VSLs should be the lowest possible.  The protections and requirements already afforded to Vendor remote access to PACS: access control, PRAs, training, etc., already reduce the risks PACS pose to the BES.  The new requirements are a best practice, and do not have a high enough risk level to warrant a Medium or High VSL.

ACES Standard Collaborations, Segment(s) 1, 3, 4, 5, 3/10/2020

- 0 - 0

Barry Jones, On Behalf of: Rosemary Jones, Western Area Power Administration, 1,6

- 0 - 0

Agree with Duke Energy's comment.

"Since PACS poses a lower risk to the BES, Duke Energy suggests that the VSLs should be lowered and should be no higher than Low or Moderate."

 

Dmitriy Bazylyuk, 3/10/2020

- 0 - 0

Jamie Prater, 3/10/2020

- 0 - 0

No comments.

Nicolas Turcotte, Hydro-Qu?bec TransEnergie, 1, 3/10/2020

- 0 - 0

Although the CAISO acknowledges that PACS are as important to protect as the BCS in line with the FERC Order, we recommend to wait on extending the program to PACS until after the upcoming CIP-005-6, CIP-010-3 and CIP-013-1 standards have been in effect for at least a two years to allow for the processes and controls to mature, to obtain any key learnings from implementing these protections and from audit experiences including findings and areas of concerns identified by the  auditors. At that time the CAISO also proposes NERC issue a CIP-013-1 survey amongst the industry to collect recommendations for improvement of the industry’s supply chain security standard.

Monika Montez, On Behalf of: California ISO, WECC, Segments 2

- 0 - 0

If PACS was added, which I disagree with, the modified VSLs can help at the time of enforcement, but don’t help during implementation.  VSLs are not evaluated when determining how to implement CIP requirements and VSLs do not influence the level of effort applied to protect the BES.

Joshua Andersen, On Behalf of: Salt River Project, WECC, Segments 1, 3, 5, 6

- 0 - 0

Richard Jackson, U.S. Bureau of Reclamation, 1, 3/10/2020

- 0 - 0

Roger Fradenburgh, On Behalf of: Nicholas Lauriat, Network and Security Technologies, 1

- 0 - 0

We agree with the modified VSLs, but believe there are underlying problems with CIP-005-7 R2.4 and R2.5 as currently proposed.

1.) The requirements assume vendor remote access sessions and impose additional monitoring requirements upon all Responsible Entities regardless of whether or not a Responsible Entity permits vendor remote access sessions. There is no need for this ongoing requirement if an entity decides not to permit vendor remote access sessions and has ensured that such sessions are either blocked or not able to be established.

We recommend R2.4 be changed to add the following, or equivalent language, before the parenthesis:

“… where permitted and not otherwise blocked or unable to be established…”

R2.5 can then be changed to add “according to R2.4 above” before the parenthesis.

2.) Per the Background Information provided at the beginning of this comment form, we propose the following change to the Applicable Systems for R2.4 and R2.5 as a means of meeting the NERC supply chain report recommendations to include (i) EACMS that provide electronic access control (excluding monitoring and logging) (p. 7), and (ii) PACS that provide physical access control, excluding alerting and logging (p. 12) while retaining current definitions:

Expand EACMS to “EACMS that provide electronic access control (excluding monitoring and logging),” or equivalent language.

Expand PACS to “PACS that provide physical access control (excluding alerting and logging)”

Andy Fuhrman, On Behalf of: Theresa Allard, Minnkota Power Cooperative Inc., 1

- 0 - 0

Carl Pineault, Hydro-Qu?bec Production, 5, 3/11/2020

- 0 - 0

Ameren agrees with and supports EEI comments.

David Jendras, Ameren - Ameren Services, 3, 3/11/2020

- 0 - 0

Glen Farmer, Avista - Avista Corporation, 5, 3/11/2020

- 0 - 0

While GSOC and GTC agree that the VSLs and VRFs associated with the addition of PACS should be lower, as discussed above, GSOC and GTC disagree with the addition of PACS to these requirements. 

Greg Davis, On Behalf of: Georgia Transmission Corporation, , Segments 1

- 0 - 0

Exelon has aligned with EEI's comment in response to this question.

Cynthia Lee, Exelon, 5, 3/11/2020

- 0 - 0

Exelon will align with EEI's comments in response to this question.

Becky Webb, Exelon, 6, 3/11/2020

- 0 - 0

Xcel Energy supports EEI comments and does not oppose the changes to VSLs.

Amy Casuscelli, On Behalf of: Xcel Energy, Inc. - MRO, WECC - Segments 1, 3, 5, 6

- 0 - 0

NYISO doesn’t understand the applicability for controls for remote access regarding PACS devices as implied within CIP-005 remote access requirements.

ISO/RTO Council Standards Review Committee 2019-03 Supply Chain Risks, Segment(s) 2, 3/11/2020

- 0 - 0

Westar Energy, an Evergy company, supports Edison Electric Institutes responses to Question 3.

Douglas Webb, 3/11/2020

- 0 - 0

Exelon will align with EEI's comments in response to this question.

Kinte Whitehead, Exelon, 3, 3/11/2020

- 0 - 0

CHPD agrees that PACS pose a lower risk to the BES than other classifications (BCA, EACMS, and PCA).  PACS have no 15-minute BES impact and no access to BCS or ESP.  CHPD believes that PACS should be excluded from Project 2019-03 for CIP-010 and CIP-013 due to their lower risk to the BES.  CHPD instead recommends a best practice approach and adequate cyber security controls be applied to PACS for the same justification as to why they were applied to PCAs in the Cyber Security Supply Chain Risks Staff Report and Recommended Actions (May 17, 2019, p. 21-22)

PUD No. 1 of Chelan County , Segment(s) 1, 3, 6, 3/11/2020

- 0 - 0

EEI supports the modifications made to the VSLs.

Mark Gray, On Behalf of: Edison Electric Institute, NA - Not Applicable, Segments NA - Not Applicable

- 0 - 0

Louisville Gas and Electric Company and Kentucky Utilities Company, Segment(s) 3, 5, 6, 9/6/2018

- 0 - 0

MidAmerican agrees with MRO NSRF comments.

Darnez Gresham, Berkshire Hathaway Energy - MidAmerican Energy Co., 3, 3/11/2020

- 0 - 0

Southern supports the modifications to the VSL’s.

However, see our comments in questions 1 and 2 with regard to the addition of EACMS and PACS assets to the scope of these new requirements.

Southern Company, Segment(s) 1, 3, 5, 6, 12/13/2019

- 0 - 0

RSC, Segment(s) 10, 2, 4, 5, 7, 3, 1, 6, 3/11/2020

- 0 - 0

Mark Ciufo, On Behalf of: Payam Farahbakhsh, Hydro One Networks, Inc., 1,3

- 0 - 0

Eversource Group, Segment(s) 3, 1, 4/12/2019

- 0 - 0

Jeff Icke, Colorado Springs Utilities, 5, 3/11/2020

- 0 - 0

Rachel Coyne, Texas Reliability Entity, Inc., 10, 3/11/2020

- 0 - 0

Tampa Elecric supports the modifications made to the VSLs.

Ronald Donahey, TECO - Tampa Electric Co., 3, 3/11/2020

- 0 - 0

Based on response under question #2 above.

LCRA Compliance, Segment(s) 6, 5, 1, 5/11/2015

- 0 - 0

Maryanne Darling-Reich, On Behalf of: Black Hills Corporation, MRO, WECC, Segments 1, 3, 5, 6

- 0 - 0

Jesus Sammy Alcaraz, Imperial Irrigation District, 1, 3/11/2020

- 0 - 0

Marc Donaldson, Tacoma Public Utilities (Tacoma, WA), 3, 3/11/2020

- 0 - 0

Wayne Guttormson, SaskPower, 1, 3/11/2020

- 0 - 0

Hot Answers

MidAmerican agrees with MRO NSRF comments.

Terry Harbour, On Behalf of: Berkshire Hathaway Energy - MidAmerican Energy Co., , Segments 1, 3

- 0 - 0

Please see comments submitted by Edison Electric Institute

Kenya Streeter, Edison International - Southern California Edison Company, 6, 3/11/2020

- 0 - 0

Other Answers

Some smaller entities may not have the resouces or time to allocate with only a one year implementation.  Typically our budgets are very tight and are set one year in advance, in October.  A longer implementaiton time assures we have resouces that can be allocated through the annual budget process.

Kevin Conway, Public Utility District No. 1 of Pend Oreille County, 1, 1/28/2020

- 1 - 0

18 month is more reasonable since 12 month will be hard for entities that have many vendors to meet the requirement.

Tho Tran, 2/26/2020

- 0 - 0

Kelsi Rigby, 2/27/2020

- 0 - 0

Tim Womack, 3/2/2020

- 0 - 0

ATC reccommends the SDT modify the current implementation plan to allow entities 18 months to fully implement the proposed changes.

LaTroy Brumfield, American Transmission Company, LLC, 1, 3/2/2020

- 0 - 0

We propose an 18 month implementation plan in order to address change management: understand the impact to existing programs, processes and documentation, revise existing documentation, develop and implement changes and test changes for integrity.

sean erickson, Western Area Power Administration, 1, 3/2/2020

- 0 - 0

NO.  Should be 48-months, or longer.

Marty Hostler, Northern California Power Agency, 4, 3/2/2020

- 0 - 0

Should be 48-months or longer.

Dennis Sismaet, Northern California Power Agency, 6, 3/3/2020

- 0 - 0

Should be 48 months or longer.

Scott Tomashefsky, 3/3/2020

- 0 - 0

Bruce Reimer, 3/5/2020

- 0 - 0

Duke Energy recommends a 24-month implementation plan as technical upgrades are likely necessary to meet the Reliability Standards’ security objectives, which could involve a longer time-horizon, capital budgets and planning cycles.

Duke Energy, Segment(s) 1, 5, 6, 3, 12/13/2019

- 0 - 0

The NSRF recommends an overall 18-month implementation plan.  The SDT is already changing yet to be effective Standards whereby applicable entities will need to prove compliance then add additional compliance attributes (PACS and EACMS). There may be new entities who will need to start a new portion of their compliance program to satisfy these new attributes.  Recommend an 18-month implementation plan. 

Dana Klem, On Behalf of: MRO - MRO - Segments 1, 2, 3, 4, 5, 6

- 1 - 0

Anthony Jablonski, ReliabilityFirst , 10, 3/6/2020

- 0 - 0

GSOC and GTC do not agree that the addition of EACMS to the Supply Chain Standards is only administrative in nature. 

The current applicability consists only of High and Medium Impact BES Cyber Systems and associated Protected Cyber Assets.  The nature and makeup of systems that perform the function of electronic access control are materially different than those that perform functions of BES Cyber Systems.  For instance, consider a substation environment.  One can reasonably envision a program that consists entirely of protective relays, remote terminal units, data concentrator, carrier radios, etc.  Note that the nature of all of these systems are embedded.  Introduction of electronic access control systems introduces entirely new classes of infrastructure, including software that may not even be considered in an entity’s existing program.  Therefore, we strongly disagree with the assertion that the changes are administrative. 

Furthermore, budgeting and planning efforts within most electric utility organizations occur at least annually with budget and/or project planning and finalization for each year occurring in advance of the implementing year.  Often, major system replacements and upgrades are planned more than a year in advance of the anticipated implementing year.  Further, responsible entities with contract/procurement management systems that are facilitating their CIP-013 compliance may have technical/programming needs to modify these corporate procurement systems to include EACMS for compliance reporting purposes. 

For these reasons, GSOC and GTC recommend a 24 month implementation plan.

Andrea Barclay, 3/6/2020

- 1 - 0

OPG supports RSC comments.

Constantin Chitescu, Ontario Power Generation Inc., 5, 3/6/2020

- 0 - 0

The addition of system-to-system access will take defining and further investigation; BPA believes this is a larger change than we can accomplish in 12 months. Also, Projects 2016-02 and 2019-03 definitions and implementation dates must be reconciled.

Andrea Jessup, On Behalf of: Bonneville Power Administration, WECC, Segments 1, 3, 5, 6

- 0 - 0

SDG&E supports EEI's recommendation that the SDT expand the proposed time for the implementation plan to 18 months.

Jennifer Wright, Sempra - San Diego Gas and Electric, 5, 3/6/2020

- 0 - 0

David Reinecke, On Behalf of: Seminole Electric Cooperative, Inc., , Segments 1, 3, 4, 5, 6

- 0 - 0

NPCC recommends an 18 or 24 month Implementation Plan due to entity budget cycles and significant increases in scope for the entity.

Leonard Kula, On Behalf of: Independent Electricity System Operator, , Segments 2

- 0 - 0

FE recommends that the SDT expand the proposed time for implementation plan to 18 months.  The addition of EACMS and PACS will result in a significant expansion in scope for both hardware and software covered under existing contracts.  Entities will need to modify existing policies and processes and negotiate modified contracts with existing vendors to cover new equipment and systems.  In addition, these new requirements will require conducting negotiations with new vendors.  In all cases, such efforts are time consuming, especially for entities that have many vendors in multiple jurisdictions.  Therefore, we feel additional time will be required to implement the standard.

FE Voter, Segment(s) 1, 3, 5, 6, 4, 10/31/2019

- 0 - 0

PG&E agrees with the proposed 12-month implementation plan.  PG&E believes the Cyber Assets being brought into scope for this modification should be able to follow the same plans and processes being developed for the BES Cyber Systems (BCS) under CIP-013-1.  PG&E does not anticipate significant changes to the plans or processes would need to be done exempt for an indicating that EACMS and PACS must be covered, and believes the education of personnel handling the procurement and implementation of the Part 1.2 controls for EACMS and PACS should be able to be done within the 12-month interval.

PG&E All Segments, Segment(s) 1, 3, 5, 2/10/2020

- 0 - 0

Anton Vu, Los Angeles Department of Water and Power, 6, 3/9/2020

- 0 - 0

From participation NERC and industry discussions, it appears that the basis for a 12-month implementation centers on an assumption that EACMS and PACS vendors are the same for high and medium impact BES Cyber Systems. This supposition would make it appear that it is a straightforward expansion of existing Supply Chain programs to EACMS and PACS. This is not true in all cases. Notably, the high (control center) and medium (ex. substation) impact environments are very different. 

CEHE suggest that 12 months is not sufficient and would like to propose a 24 month implementation plan instead.

Eli Rivera, On Behalf of: CenterPoint Energy Houston Electric, LLC, Texas RE, Segments NA - Not Applicable

- 0 - 0

Alliant Energy agrees with NSRF and EEI’s comments recommending that the SDT expand the proposed time for implementation plan to 18 months. The addition of EACMS and PACS represents a significant expansion in scope for both hardware and software covered under existing contracts. Entities have a large volume of vendors each of which has different contracts in place.  Thus, for each of the vendors, entities will need to modify existing policies and processes and negotiate modified contracts with the many existing vendors to cover new equipment and systems.  In addition, the new requirements will require conducting negotiations with new vendors.

Jenifer Holmes, On Behalf of: Alliant Energy Corporation Services, Inc. - MRO, RF - Segments 4

- 0 - 0

Exelon is aligning with EEI's comments for this question.

Daniel Gacek, Exelon, 1, 3/9/2020

- 0 - 0

Please see comments submitted by Edison Electric Institute

Ayman Samaan, 3/9/2020

- 0 - 0

Although adding the words EACMs and PACS to the requirements seems fairly innocuous. It can in fact be a significant

impact to an Entity’s CIP compliance program and approach. Entities may need to evaluate, procure and implement

new technologies and processes to incorporate these systems.

Recommend a 24 month implementation.

John Galloway, On Behalf of: Michael Puscas, ISO New England, Inc., 2

- 0 - 0

Dania Colon, Orlando Utilities Commission, 5, 3/10/2020

- 0 - 0

ACES Standard Collaborations, Segment(s) 1, 3, 4, 5, 3/10/2020

- 0 - 0

18 months minimum

Barry Jones, On Behalf of: Rosemary Jones, Western Area Power Administration, 1,6

- 0 - 0

Agree with Duke Energy's comment.

"Duke Energy recommends a 24-month implementation plan as technical upgrades are likely necessary to meet the Reliability Standards’ security objectives, which could involve a longer time-horizon, capital budgets and planning cycles."

Dmitriy Bazylyuk, 3/10/2020

- 0 - 0

Entergy proposes an 18 month implementation plan as was approved via Project 2016-03 for these standards. While the requirement language does not change, the inclusion of systems that were not originally included in the Project 2016-03 scope should allow for the same timeline of implementation as entities must again evaluate compliance strategies for new sets of hardware and/or software that may not be compatible with the entity’s expected processes for BCA and PCA assets.

Jamie Prater, 3/10/2020

- 0 - 0

Considering the scope of changes introduced by SDT, we recommend an 18 or 24 month implementation plan.

Nicolas Turcotte, Hydro-Qu?bec TransEnergie, 1, 3/10/2020

- 0 - 0

The IRC SRC recommends an 18 or 24-month Implementation Plan to allow sufficient lead time for an entity to incorporate changes into their programs as time will be needed to justify costs and obtain budgets as well as developing approaches to accommodate the expansion of assets included in scope. Depending upon how an entity implemented their initial Supply Chain Standards program, the proposed changes to CIP-005, CIP-010 and CIP-013 could result in significant impacts to an entity’s program and may not be as simple as merely adding a few additional systems. For these entities, they will need to develop and implement a different process for EACMS and PACS systems, so the IRC SRC requests the SDT allow additional time.

Monika Montez, On Behalf of: California ISO, WECC, Segments 2

- 0 - 0

The proposed implementation timeline may not allow enough time for industry to properly gauge the effects of the preceding version of standards Subject to Enforcement. Based on the outcomes of the yet to become effective versions of the Standards, additional budget and time could be needed to implement the proposed updates. SRP would like to recommend an implementation timeline of 15 to 18 calendar months, starting in the next calendar quarter of the approval of CIP-005-7, CIP-010-4, and CIP-013-2.

Joshua Andersen, On Behalf of: Salt River Project, WECC, Segments 1, 3, 5, 6

- 0 - 0

Reclamation recommends a 24 month implementation plan after the applicable governmental entity’s order approving the standard to allow entities flexibility to determine the appropriate implementation.

Richard Jackson, U.S. Bureau of Reclamation, 1, 3/10/2020

- 0 - 0

Because EACMS and PACS may be located outside of any Electronic Security Perimeter (Intermediate Systems MUST be outside any ESP), N&ST believes entities *could* find it necessary to define and implement controls for CIP-005 R2.4 and R2.5 for EACMS and PACS that are entirely different than the ones they have implemented for BES Cyber Systems and PCAs. Therefore, N&ST believes the implementation plan duration should be 18 months, not 12 months.

Roger Fradenburgh, On Behalf of: Nicholas Lauriat, Network and Security Technologies, 1

- 0 - 0

MPC does not agree that the addition of EACMS to the Supply Chain Standards is only administrative in nature.  Budgeting and planning efforts within most electric utility organizations occur at least annually with budget and/or project planning and finalization for each year occurring in advance of the implementing year.  Often, major system replacements and upgrades are planned more than a year in advance of the anticipated implementing year.  Further, responsible entities with contract/procurement management systems that are facilitating their CIP-013 compliance may have technical/programming needs to modify these corporate procurement systems to include EACMS for compliance reporting purposes.  For these reasons, MPC recommends an 18 month implementation plan.

Andy Fuhrman, On Behalf of: Theresa Allard, Minnkota Power Cooperative Inc., 1

- 0 - 0

Carl Pineault, Hydro-Qu?bec Production, 5, 3/11/2020

- 0 - 0

Ameren agrees with and supports EEI comments.

David Jendras, Ameren - Ameren Services, 3, 3/11/2020

- 0 - 0

Glen Farmer, Avista - Avista Corporation, 5, 3/11/2020

- 0 - 0

GSOC and GTC do not agree that the addition of EACMS to the Supply Chain Standards is only administrative in nature. 

The current applicability consists only of High and Medium Impact BES Cyber Systems and associated Protected Cyber Assets.  The nature and makeup of systems that perform the function of electronic access control are materially different than those that perform functions of BES Cyber Systems.  For instance, consider a substation environment.  One can reasonably envision a program that consists entirely of protective relays, remote terminal units, data concentrator, carrier radios, etc.  Note that the nature of all of these systems are embedded.  Introduction of electronic access control systems introduces entirely new classes of infrastructure, including software that may not even be considered in an entity’s existing program.  Therefore, we strongly disagree with the assertion that the changes are administrative. 

Furthermore, budgeting and planning efforts within most electric utility organizations occur at least annually with budget and/or project planning and finalization for each year occurring in advance of the implementing year.  Often, major system replacements and upgrades are planned more than a year in advance of the anticipated implementing year.  Further, responsible entities with contract/procurement management systems that are facilitating their CIP-013 compliance may have technical/programming needs to modify these corporate procurement systems to include EACMS for compliance reporting purposes. 

For these reasons, GSOC and GTC recommend a 24 month implementation plan.

Greg Davis, On Behalf of: Georgia Transmission Corporation, , Segments 1

- 0 - 0

Exelon has aligned with EEI's comment in response to this question.

Cynthia Lee, Exelon, 5, 3/11/2020

- 0 - 0

Exelon will align with EEI's comments in response to this question.

Becky Webb, Exelon, 6, 3/11/2020

- 0 - 0

Xcel Energy supports EEI comments on this question and believes that an 18 month implementation period would be more appropriate.

Amy Casuscelli, On Behalf of: Xcel Energy, Inc. - MRO, WECC - Segments 1, 3, 5, 6

- 0 - 0

The IRC SRC recommends an 18- or 24-month Implementation Plan to allow sufficient lead time for an entity to incorporate changes into their programs as time will be needed to justify costs and obtain budgets as well as developing approaches to accommodate the expansion of assets included in scope. Depending upon how an entity implemented their initial Supply Chain Standards program, the proposed changes to CIP-005, CIP-010 and CIP-013 could result in significant impacts to an entity’s program and may not be as simple as merely adding a few additional systems. For these entities, they will need to develop and implement a different process for EACMS and PACS systems. Therefore, the IRC SRC requests the SDT allow additional time.

Note: CAISO (segment 2, WECC region) also joins the IRC SRC in the comments provided in response to Question 4.

ISO/RTO Council Standards Review Committee 2019-03 Supply Chain Risks, Segment(s) 2, 3/11/2020

- 0 - 0

Westar Energy, an Evergy company, supports Edison Electric Institutes responses to Question 4

Douglas Webb, 3/11/2020

- 0 - 0

Exelon will align with EEI's comments in response to this question.

Kinte Whitehead, Exelon, 3, 3/11/2020

- 0 - 0

PUD No. 1 of Chelan County , Segment(s) 1, 3, 6, 3/11/2020

- 0 - 0

EEI recommends that the SDT expand the proposed time for implementation plan to 18 months.  The addition of EACMS and PACS represents a significant expansion in scope for both hardware and software covered under existing contracts.  Entities have a large volume of vendors each of which has different contracts in place.  Thus, for each of the vendors, entities will need to modify existing policies and processes and negotiate modified contracts with the many existing vendors to cover new equipment and systems.  In addition, the new requirements will require conducting negotiations with new vendors.  In all cases, such efforts are time consuming, especially for entities that have many vendors in multiple jurisdictions.  Therefore, the additional time to implement the standard is necessary.  

Mark Gray, On Behalf of: Edison Electric Institute, NA - Not Applicable, Segments NA - Not Applicable

- 0 - 0

Louisville Gas and Electric Company and Kentucky Utilities Company, Segment(s) 3, 5, 6, 9/6/2018

- 0 - 0

MidAmerican agrees with MRO NSRF comments.

Darnez Gresham, Berkshire Hathaway Energy - MidAmerican Energy Co., 3, 3/11/2020

- 0 - 0

Southern recommends that the SDT expand the proposed time for implementation plan to 18 months and suggests for the SDT to consider budget cycles for possible technological upgrades needed before implementation.  In this case, 18 months would be a fair alternate time frame. The addition of EACMS and PACS represents a significant expansion in scope for both hardware and software covered under existing contracts.  Entities have a large volume of vendors each of which has different contracts in place.  Thus, for each of the vendors, entities will need to modify existing policies and processes and negotiate modified contracts with the many existing vendors to cover new equipment and systems.  In addition, the new requirements will require conducting negotiations with new vendors.  In all cases, such efforts are time consuming, especially for entities that have many vendors in multiple jurisdictions.  Therefore, the additional time to implement the standard is necessary.

Southern Company, Segment(s) 1, 3, 5, 6, 12/13/2019

- 0 - 0

NPCC recommends an 18 or 24 month Implementation Plan due to entity budget cycles and significant increases in scope for the entity.

RSC, Segment(s) 10, 2, 4, 5, 7, 3, 1, 6, 3/11/2020

- 0 - 0

We recommend a longer implementation period than the proposed 12 months.

Mark Ciufo, On Behalf of: Payam Farahbakhsh, Hydro One Networks, Inc., 1,3

- 0 - 0

Eversource suggests an 18-month implementation plan due to current experience with adding vendors to the initial Supply Chain project.

Eversource Group, Segment(s) 3, 1, 4/12/2019

- 0 - 0

Jeff Icke, Colorado Springs Utilities, 5, 3/11/2020

- 0 - 0

Rachel Coyne, Texas Reliability Entity, Inc., 10, 3/11/2020

- 0 - 0

Tampa Elecric supports EEI recommendation that the SDT expand the proposed time for implementation plan to 18 months. The addition of EACMS and PACS represents a significant expansion in scope for both hardware and software covered under existing contracts. Entities have a large volume of vendors each of which has different contracts in place. Thus, for each of the vendors, entities will need to modify existing policies and processes and negotiate modified contracts with the many existing vendors to cover new equipment and systems. In addition, the new requirements will require conducting negotiations with new vendors. In all cases, such efforts are time consuming, especially for entities that have many vendors in multiple jurisdictions. Therefore, the additional time to implement the standard is necessary.

Ronald Donahey, TECO - Tampa Electric Co., 3, 3/11/2020

- 0 - 0

LCRA Compliance, Segment(s) 6, 5, 1, 5/11/2015

- 0 - 0

We would prefer an 18 month implementation to better accommodate a budget cycle

Maryanne Darling-Reich, On Behalf of: Black Hills Corporation, MRO, WECC, Segments 1, 3, 5, 6

- 0 - 0

Jesus Sammy Alcaraz, Imperial Irrigation District, 1, 3/11/2020

- 0 - 0

Marc Donaldson, Tacoma Public Utilities (Tacoma, WA), 3, 3/11/2020

- 0 - 0

Support the MRO comments.

Wayne Guttormson, SaskPower, 1, 3/11/2020

- 0 - 0

Hot Answers

MidAmerican agrees with MRO NSRF comments.

Terry Harbour, On Behalf of: Berkshire Hathaway Energy - MidAmerican Energy Co., , Segments 1, 3

- 0 - 0

Please see comments submitted by Edison Electric Institute

Kenya Streeter, Edison International - Southern California Edison Company, 6, 3/11/2020

- 0 - 0

Other Answers

Kevin Conway, Public Utility District No. 1 of Pend Oreille County, 1, 1/28/2020

- 0 - 0

N/A

Tho Tran, 2/26/2020

- 0 - 0

Kelsi Rigby, 2/27/2020

- 0 - 0

Tim Womack, 3/2/2020

- 0 - 0

LaTroy Brumfield, American Transmission Company, LLC, 1, 3/2/2020

- 0 - 0

 The costs associated with ensuring supply chain and CIP-010 R1.6 and CIP-013 R1.2.5 - integrity of software in the supply chain, as well as the requirement to have multi-departmental personnel, updates to existing documentation, new documentation, changes to systems and contract changes will cost industry and ratepayers many thousands of dollars in personnel, systems and process work.

sean erickson, Western Area Power Administration, 1, 3/2/2020

- 1 - 0

NO. NERC needs to include the real costs of all new regulations they are imposing not the low ball figures they have provided in the past. 

The costs impacts on entities due to the constant changing of Standards and having entities change documents we just changed needs to be included.  Lost productivity time cost of getting modified documents and budgets approved and implemented (once again due to NERC program changes) by our governing boards cost of lost opportunities!

Also they need to include costs for specific new FTEs (SMEs, persons to insure project controls in place, persons to quality check new controls).  Plus they need to include cost of changing/Updating existing plans and policies, cost to send out new RFPs to Vendors, cost for additional/updated Vendor reviews per another set a CIP standards changes. 

NERC is proposing these new changes when the Supply Chain Standard has not even taken effect yet nor have prior approved CIP-005 and 10 July 1, 2020 effectives versions.  

And now they are proposing changes to these standards, again.  They are working on more proposed changes, see project 2016-02.  In my view all these multiple changes and proposals are unnecessary and costly to entities; let only confusing to use, our governing boards, and have little, if any, real reliability value. 

Marty Hostler, Northern California Power Agency, 4, 3/2/2020

- 1 - 0

NERC needs to include the real costs of all new regulations they are imposing not the low ball figures they have provided in the past. 

The costs impacts on entities due to the constant changing of Standards and having entities change documents we just changed needs to be included.  Lost productivity time cost of getting modified documents and budgets approved and implemented (once again due to NERC program changes) by our governing boards cost of lost opportunities!

 

Also they need to include costs for specific new FTEs (SMEs, persons to insure project controls in place, persons to quality check new controls).  Plus they need to include cost of changing/Updating existing plans and policies, cost to send out new RFPs to Vendors, cost for additional/updated Vendor reviews per another set a CIP standards changes. 

 

NERC is proposing these new changes when the Supply Chain Standard has not even taken effect yet nor have prior approved CIP-005 and 10 July 1, 2020 effectives versions.  

 

And now they are proposing changes to these standards, again.  They are working on more proposed changes, see project 2016-02.  In my view all these multiple changes and proposals are unnecessary and costly to entities; let only confusing to use, our governing boards, and have little, if any, real reliability value. 

Dennis Sismaet, Northern California Power Agency, 6, 3/3/2020

- 0 - 0

NERC needs to include the real costs of all new regulations they are imposing not the low ball figures they have provided in the past. 

The costs impacts on entities due to the constant changing of Standards and having entities change documents we just changed needs to be included.  Lost productivity time cost of getting modified documents and budgets approved and implemented (once again due to NERC program changes) by our governing boards cost of lost opportunities!

Also they need to include costs for specific new FTEs (SMEs, persons to insure project controls in place, persons to quality check new controls).  Plus they need to include cost of changing/Updating existing plans and policies, cost to send out new RFPs to Vendors, cost for additional/updated Vendor reviews per another set a CIP standards changes. 

 

NERC is proposing these new changes when the Supply Chain Standard has not even taken effect yet nor have prior approved CIP-005 and 10 July 1, 2020 effectives versions.  

And now they are proposing changes to these standards, again.  They are working on more proposed changes, see project 2016-02.  In my view all these multiple changes and proposals are unnecessary and costly to entities; let only confusing to use, our governing boards, and have little, if any, real reliability value. 

Scott Tomashefsky, 3/3/2020

- 0 - 0

A scope change of applicable CIP system always cause additional compliance cost. We don’t know whether the current change is cost-effective or not.

Bruce Reimer, 3/5/2020

- 0 - 0

Duke Energy, Segment(s) 1, 5, 6, 3, 12/13/2019

- 0 - 0

One member entity estimated the following costs and provides a recommendation:

Depending on the entity, the costs associated with the proposed changes may range between an annualized cost of $80K (80 to 100 hours per person) and $500K per entity. This does not include capital expenditures for technologies which manage vendor access, which may exceed $5M per entity.

This is based on the need to:

a. Develop, update and implement procedures and training for multiple departments and their personnel.

b. Perform updates to existing categorization processes to ensure the identification and controls exist to meet and exceed the requirements in the revisions.

c. Identify existing or implement new technologies to manage supplier or vendor remote access solutions. This includes efforts in integration and changes to systems, contracts, processes and internal compliance program metrics.

Recommend utilizing existing CIP program processes to meet the requirements. For example, CIP-013 R1.5 requires software integrity in the supply chain. CIP-010 R1.6 requires software integrity. CIP-007 R2 also requires integrity in software security patches. Aligning those standards into a single meaningful standard could improve cost effectiveness.

Dana Klem, On Behalf of: MRO - MRO - Segments 1, 2, 3, 4, 5, 6

- 1 - 0

Anthony Jablonski, ReliabilityFirst , 10, 3/6/2020

- 0 - 0

While GSOC and GTC acknowledge the current flexibility in implementation that the CIP reliability standards provide, the inclusion of PACS in the CIP reliability standards would not be cost-effective as it will provide no direct benefits to the reliability of the BES.  Further, as these systems are not included in the FERC directive, it is certainly not cost-effective to unnecessarily include them.

Andrea Barclay, 3/6/2020

- 0 - 0

Constantin Chitescu, Ontario Power Generation Inc., 5, 3/6/2020

- 0 - 0

BPA supports WAPA’s comment as follows:

“The costs associated with ensuring supply chain and CIP-010 R1.6 and CIP-013 R1.2.5 - integrity of software in the supply chain, as well as the requirement to have multi-departmental personnel, updates to existing documentation, new documentation, changes to systems and contract changes will cost industry and ratepayers many thousands of dollars in personnel, systems and process work.”

Andrea Jessup, On Behalf of: Bonneville Power Administration, WECC, Segments 1, 3, 5, 6

- 1 - 0

Jennifer Wright, Sempra - San Diego Gas and Electric, 5, 3/6/2020

- 0 - 0

David Reinecke, On Behalf of: Seminole Electric Cooperative, Inc., , Segments 1, 3, 4, 5, 6

- 0 - 0

No Comments.

Leonard Kula, On Behalf of: Independent Electricity System Operator, , Segments 2

- 0 - 0

FE Voter, Segment(s) 1, 3, 5, 6, 4, 10/31/2019

- 0 - 0

PG&E cannot agree the modifications are cost effective at this time.  This is based on the current effort to implement CIP-013-1 has not been completed and a full understanding of the current costs is not known.  PG&E would have preferred to answer this question as “Unknown”, but the option was not available.

PG&E All Segments, Segment(s) 1, 3, 5, 2/10/2020

- 0 - 0

Anton Vu, Los Angeles Department of Water and Power, 6, 3/9/2020

- 0 - 0

Eli Rivera, On Behalf of: CenterPoint Energy Houston Electric, LLC, Texas RE, Segments NA - Not Applicable

- 0 - 0

Alliant Energy agrees with the NSRF’s comments.

Jenifer Holmes, On Behalf of: Alliant Energy Corporation Services, Inc. - MRO, RF - Segments 4

- 0 - 0

Exelon is aligning with EEI's comments for this question.

Daniel Gacek, Exelon, 1, 3/9/2020

- 0 - 0

Please see comments submitted by Edison Electric Institute

Ayman Samaan, 3/9/2020

- 0 - 0

John Galloway, On Behalf of: Michael Puscas, ISO New England, Inc., 2

- 0 - 0

Dania Colon, Orlando Utilities Commission, 5, 3/10/2020

- 0 - 0

ACES Standard Collaborations, Segment(s) 1, 3, 4, 5, 3/10/2020

- 0 - 0

NERC should perform an impact analysis as part of the SAR process. Every change impacts existing documentation and process stacks.

Barry Jones, On Behalf of: Rosemary Jones, Western Area Power Administration, 1,6

- 0 - 0

In order to properly evaluate and fund required changes a longer implementation period of 24 months is required. This is necessary to obtain possible funding and process changes that would be necessary. 

Dmitriy Bazylyuk, 3/10/2020

- 0 - 0

Jamie Prater, 3/10/2020

- 0 - 0

No comments

Nicolas Turcotte, Hydro-Qu?bec TransEnergie, 1, 3/10/2020

- 0 - 0

Although the CAISO acknowledges that EACMS and PACS are as important to protect as the BCS in line with the FERC Order, we recommend to wait on wait with extending the program to EACMS and PACS until after the upcoming CIP-005-6, CIP-010-3 and CIP-013-1 standards have been in effect for at least a two years to allow for the processes and controls to mature, to obtain any key learnings from implementing these protections and from audit experiences including findings and areas of concerns identified by the auditors to ensure they are implemented in the most cost-effective manner. At that time the CAISO also proposes NERC issue a CIP-013-1 survey amongst the industry to collect recommendations for improvement of the industry’s supply chain security standard.

Monika Montez, On Behalf of: California ISO, WECC, Segments 2

- 0 - 0

The FERC order states this is only an “increased paperwork burden” which I disagree with.  Where does this include the actual ongoing monitoring of activity and maintaining an adequate level of training personnel across multiple parts of the power systems that know how to respond? 

Joshua Andersen, On Behalf of: Salt River Project, WECC, Segments 1, 3, 5, 6

- 0 - 0

Prior to proposing additional modifications, Reclamation recommends each SDT take additional time to effectively define the scope of each Standard Authorization Request to minimize the costs associated with the planning and adjustments required to achieve compliance with frequently changing requirements. This will provide entities economic relief by allowing technical compliance with current standards.

Richard Jackson, U.S. Bureau of Reclamation, 1, 3/10/2020

- 0 - 0

Roger Fradenburgh, On Behalf of: Nicholas Lauriat, Network and Security Technologies, 1

- 0 - 0

Andy Fuhrman, On Behalf of: Theresa Allard, Minnkota Power Cooperative Inc., 1

- 0 - 0

Carl Pineault, Hydro-Qu?bec Production, 5, 3/11/2020

- 0 - 0

Ameren agrees with and supports EEI comments.

David Jendras, Ameren - Ameren Services, 3, 3/11/2020

- 0 - 0

Glen Farmer, Avista - Avista Corporation, 5, 3/11/2020

- 0 - 0

While GSOC and GTC acknowledge the current flexibility in implementation that the CIP reliability standards provide, the inclusion of PACS in the CIP reliability standards would not be cost-effective as it will provide no direct benefits to the reliability of the BES.  Further, as these systems are not included in the FERC directive, it is certainly not cost-effective to unnecessarily include them.

Greg Davis, On Behalf of: Georgia Transmission Corporation, , Segments 1

- 0 - 0

Exelon has aligned with EEI's comment in response to this question.

Cynthia Lee, Exelon, 5, 3/11/2020

- 0 - 0

Exelon will align with EEI's comments in response to this question.

Becky Webb, Exelon, 6, 3/11/2020

- 0 - 0

Xcel Energy takes no position on the cost effectiveness of the proposed changes.

Amy Casuscelli, On Behalf of: Xcel Energy, Inc. - MRO, WECC - Segments 1, 3, 5, 6

- 0 - 0

ISO/RTO Council Standards Review Committee 2019-03 Supply Chain Risks, Segment(s) 2, 3/11/2020

- 0 - 0

Westar Energy, an Evergy company, supports Edison Electric Institutes responses to Question ​5.

Douglas Webb, 3/11/2020

- 0 - 0

Exelon will align with EEI's comments in response to this question.

Kinte Whitehead, Exelon, 3, 3/11/2020

- 0 - 0

PUD No. 1 of Chelan County , Segment(s) 1, 3, 6, 3/11/2020

- 0 - 0

Mark Gray, On Behalf of: Edison Electric Institute, NA - Not Applicable, Segments NA - Not Applicable

- 0 - 0

Louisville Gas and Electric Company and Kentucky Utilities Company, Segment(s) 3, 5, 6, 9/6/2018

- 0 - 0

MidAmerican agrees with MRO NSRF comments.

Darnez Gresham, Berkshire Hathaway Energy - MidAmerican Energy Co., 3, 3/11/2020

- 0 - 0

Southern agrees that the FERC directives can be executed in a cost-effective manner.  There will be an undue cost and burden initially to conduct business another way by adding EACMS and PACS to CIP-005 R2.4 and R2.5.  Other costs will include providing new technology if not already present to track, store, and recall the data addressing the assessments provided by CIP vendors. One suggestion would be to allow the additional time suggested in Question 4 to consider those budget cycles for any possible technology upgrades.

Southern Company, Segment(s) 1, 3, 5, 6, 12/13/2019

- 0 - 0

RSC, Segment(s) 10, 2, 4, 5, 7, 3, 1, 6, 3/11/2020

- 0 - 0

Mark Ciufo, On Behalf of: Payam Farahbakhsh, Hydro One Networks, Inc., 1,3

- 0 - 0

No comment

Eversource Group, Segment(s) 3, 1, 4/12/2019

- 0 - 0

Jeff Icke, Colorado Springs Utilities, 5, 3/11/2020

- 0 - 0

Texas RE does not have comments on this question.

Rachel Coyne, Texas Reliability Entity, Inc., 10, 3/11/2020

- 0 - 0

Tampa Electric takes no position as to the cost effectiveness of the proposed changes

Ronald Donahey, TECO - Tampa Electric Co., 3, 3/11/2020

- 0 - 0

LCRA Compliance, Segment(s) 6, 5, 1, 5/11/2015

- 0 - 0

Re-use of existing terms is easier and more cost effective than introducing new terms and/or requirements.

Maryanne Darling-Reich, On Behalf of: Black Hills Corporation, MRO, WECC, Segments 1, 3, 5, 6

- 0 - 0

Jesus Sammy Alcaraz, Imperial Irrigation District, 1, 3/11/2020

- 0 - 0

Marc Donaldson, Tacoma Public Utilities (Tacoma, WA), 3, 3/11/2020

- 0 - 0

Wayne Guttormson, SaskPower, 1, 3/11/2020

- 0 - 0

Hot Answers

MidAmerican agrees with MRO NSRF comments.

Terry Harbour, On Behalf of: Berkshire Hathaway Energy - MidAmerican Energy Co., , Segments 1, 3

- 0 - 0

Please see comments submitted by Edison Electric Institute

Kenya Streeter, Edison International - Southern California Edison Company, 6, 3/11/2020

- 0 - 0

Other Answers

None

Kevin Conway, Public Utility District No. 1 of Pend Oreille County, 1, 1/28/2020

- 0 - 0

N/A

Tho Tran, 2/26/2020

- 0 - 0

Kelsi Rigby, 2/27/2020

- 0 - 0

Tim Womack, 3/2/2020

- 0 - 0

LaTroy Brumfield, American Transmission Company, LLC, 1, 3/2/2020

- 0 - 0

1.      The NERC SAR for this order is poorly written please revise to include the FERC Order and NERC technical paper requirements

2.      Consider revising CIP-002 to identify all different Cyber System and Cyber Asset types and their ability to be accessed locally and remotely (physical and electronic). Distinguish between EACMS and PACS which provide preventive and detective controls and identify internal controls which meet the audit requirements and are agreeable to industry

sean erickson, Western Area Power Administration, 1, 3/2/2020

- 0 - 0

I feel FERC/NERC should be vetting Vendors and creating a list for us.  Similar to Underwriter Labs (UL) reviewing, vetting, and testing equipment, then stamping it for appropriate use.

Marty Hostler, Northern California Power Agency, 4, 3/2/2020

- 0 - 0

I feel FERC/NERC should be vetting Vendors and creating a list for us.  Similar to Underwriter Labs (UL) reviewing, vetting, and testing equipment, then stamping it for appropriate use.

Dennis Sismaet, Northern California Power Agency, 6, 3/3/2020

- 0 - 0

FERC/NERC should be vetting Vendors and creating a list for us.  Similar to Underwriter Labs (UL) reviewing, vetting, and testing equipment, then stamping it for appropriate use.

Scott Tomashefsky, 3/3/2020

- 0 - 0

We suggest moving revised CIP-011-2 R1.4 to CIP-013 R1.1 to address BCSI cloud services provider’s risks since it really belongs to the supply chain risk management.

Bruce Reimer, 3/5/2020

- 0 - 0

Duke Energy suggests the following:

Current CIP standards don’t require entity to go beyond ESP boundary to monitor vendor remote access.  Since all EACMS and PACS system don’t reside within an ESP, the focus of this standard will shift beyond ESP boundary, where will be required to monitor and possibly terminate such access before such traffic even gets to ESP firewall. Duke Energy believes only EACMS or PACS devices that reside within an ESP should be the focus of this standard, so original intention of CIP-005 protection at the ESP level doesn’t get derailed.

Duke Energy, Segment(s) 1, 5, 6, 3, 12/13/2019

- 0 - 0

Comments:

1.) Recommend the SDT for Project 2019-03: Cyber Security Supply Chain Risks reach out to the SDT for Project 2019-02: BCSI Access Management to explore whether the vendor-related requirements currently proposed under Project 2019-02, i.e. CIP-011-3, requirement R1, part 1.4, “to identify, assess, and mitigate risks in cases where vendors store Responsible Entity’s BES Cyber System Information,” would be a better fit with the existing requirements under CIP-013 and, if so, discuss what would be needed to incorporate those changes into CIP-013-2. Additional support for exploring this recommendation is provided below, showing the divergence in language between the two SDTs.

2.) A SDT member indicated in conversation that mitigation would be required for CIP-013-2 requirement R1. The current language of CIP-013-2, R1, part 1.1, only requires an entity to “identify and assess cyber security risks;” there is no mention of mitigation.

Conversely, the parallel SDT team working on Project 2019-02: BCSI Access Management has proposed language for CIP-011-3, requirement R1, part 1.4, that will require an entity to 

implement one or more documented information protection program(s) including “Processes to identify, assess, and mitigate risks in cases where vendors store Responsible Entity’s BES Cyber System Information.”

We request the SDT, in order to avoid duplication of requirements across multiple standards, to collaborate with the SDT for Project 2019-02 to either:

- Migrate all vendor-related requirements currently proposed under CIP-011-3, R1, Part 1.4 to CIP-013-2,

OR

- Drop any plans to introduce mitigation in CIP-011-3, R1, Part 1.4 and defer to the language in the existing, similar requirement under CIP-013-1, R1, Part 1.1.

We believe the SDT has the latitude under the SAR to undertake this consolidation per the Project Scope:

“This project will address the directives issued by FERC in Order No. 850. This project will also consider NERC staff recommendation from the Supply Chain Report. This team will work to coordinate with other ongoing CIP development projects to ensure alignment with any changes to definition or standards and requirements.”

Dana Klem, On Behalf of: MRO - MRO - Segments 1, 2, 3, 4, 5, 6

- 1 - 0

Why are Protected Cyber Asset (PCA) or Protected Cyber System (PCS) per CIP [Definitions: Project 2016-02 Modifications to CIP Standards] not considered; given that the “impact rating of the PCA [or PCS] is equal to the highest rated BCS in the same ESP?

Anthony Jablonski, ReliabilityFirst , 10, 3/6/2020

- 0 - 0

Andrea Barclay, 3/6/2020

- 0 - 0

OPG supports RSC comments.

Constantin Chitescu, Ontario Power Generation Inc., 5, 3/6/2020

- 0 - 0

Andrea Jessup, On Behalf of: Bonneville Power Administration, WECC, Segments 1, 3, 5, 6

- 0 - 0

Jennifer Wright, Sempra - San Diego Gas and Electric, 5, 3/6/2020

- 0 - 0

David Reinecke, On Behalf of: Seminole Electric Cooperative, Inc., , Segments 1, 3, 4, 5, 6

- 0 - 0

During our discussion with the SDT SME the SME indicated that mitigation would be required for CIP-013-2 R1 and TFIST request written clarification if mitigation will be required in CIP-013-2 R1.

There is an error in the R3 moderate VSL that was carried over from the previous version.  The existing text reads “…but has performed a vulnerability assessment more than 18 months ….” However, it should read “but has performed a vulnerability assessment more than 18 months, but less than 21 months ….”

Leonard Kula, On Behalf of: Independent Electricity System Operator, , Segments 2

- 0 - 0

FirstEnergy urges the SDT to develop Implementation Guidance for Industry review and comment on the proposed changes. 

FE Voter, Segment(s) 1, 3, 5, 6, 4, 10/31/2019

- 0 - 0

PG&E agrees with the EEI input on Question 6 regarding the modification to CIP-005-7, Requirement R2, Part 2.5 creating an untenable dilemma based on how it could be interpreted. This is based on the EEI comment of:

 

 “The language can be read to obligate entities to not just terminate vendor access through methods such as disabling rules within a firewall or disabling a user account for EACMS (e.g., Windows domain controller) but also to require entities to block all vendor access to the EACMS itself (i.e., install a firewall for the firewall).”

 

EEI additionally indicated that if entities are required to block all access to the EACMS by installing a separate firewall, the newly installed firewall would be an EACMS which would then need to have another firewall installed creating an endless loop of new obligations. 

 

While the EEI recommendation indicates to remove EACMS from the Applicability Section of Requirement R2, Part 2.5, PG&E believes this would result in the modification not meeting FERC’s directive in Order 850.

 

PG&E recommends the Requirement language be modified to indicate the endless loop condition is not the intended purpose of the modification, or guidance be created which clearly indicates it is not the intended purpose of the Requirement.  The preferred solution is Requirement language since Audit Teams are not bound to the wording in guidance.

PG&E All Segments, Segment(s) 1, 3, 5, 2/10/2020

- 0 - 0

Anton Vu, Los Angeles Department of Water and Power, 6, 3/9/2020

- 0 - 0

CEHE supports the additional comments as submitted by the Edison Electric Institute.

Eli Rivera, On Behalf of: CenterPoint Energy Houston Electric, LLC, Texas RE, Segments NA - Not Applicable

- 0 - 0

Alliant Energy agrees with NSRF and EEI’s comments.

Jenifer Holmes, On Behalf of: Alliant Energy Corporation Services, Inc. - MRO, RF - Segments 4

- 0 - 0

Exelon is aligning with EEI's comments for this question.

Daniel Gacek, Exelon, 1, 3/9/2020

- 0 - 0

Ayman Samaan, 3/9/2020

- 0 - 0

John Galloway, On Behalf of: Michael Puscas, ISO New England, Inc., 2

- 0 - 0

Dania Colon, Orlando Utilities Commission, 5, 3/10/2020

- 0 - 0

We would like to thank the SDT for allowing us to comment on the proposed changes.

ACES Standard Collaborations, Segment(s) 1, 3, 4, 5, 3/10/2020

- 0 - 0

1. The NERC SAR for this order is poorly written and inaccurate at best. The intent of the SAR is to communicate the ask, the specifics around what is required, and citations for the basis. Recommend revising the SAT to include the specific FERC Order and NERC technical paper requirements and recommendations.

2. Consider revising CIP-002 to identify all different Cyber System and Cyber Asset types and their ability to be accessed locally and remotely (physical and electronic). Distinguish between EACMS and PACS which provide preventive and detective controls and identify internal controls which meet the audit requirements and are agreeable to industry

Barry Jones, On Behalf of: Rosemary Jones, Western Area Power Administration, 1,6

- 0 - 0

Dmitriy Bazylyuk, 3/10/2020

- 0 - 0

Jamie Prater, 3/10/2020

- 0 - 0

To prevent possible confusion we suggest that all modifications proposed for CIP-005 and CIP-010 should be documented in one CIP standard (CIP-013).

Nicolas Turcotte, Hydro-Qu?bec TransEnergie, 1, 3/10/2020

- 0 - 0

The IRC SRC recommends the SDT for Project 2019-03: Cyber Security Supply Chain Risks reach out to the SDT for Project 2019-02: BCSI Access Management to explore whether the vendor-related requirements currently proposed under Project 2019-02; i.e. CIP-011-3, requirement R1, part 1.4  “to identify, assess, and mitigate risks in cases where vendors store Responsible Entity’s BES Cyber System Information,” would be a better fit with the existing requirements under CIP-013 and, if so, discuss what would be needed to incorporate those changes into CIP-013-2. Additional support for exploring this recommendation is provided below in the form of a divergence in language between the two SDTs.

During discussion with a member of the SDT, the member indicated mitigation would be required for CIP-013-2 requirement R1. Currently, the language of CIP-013-2, R1, part 1.1 only requires an entity to “identify and assess cyber security risks” and not mitigate them as detailed below.

“One or more process(es) used in planning for the procurement of BES Cyber Systems and their associated EACMS and PACS to identify and assess cyber security risk(s) to the Bulk Electric System from vendor products or services resulting from: (i) procuring and installing vendor equipment and software; and (ii) transitions from one vendor(s) to another vendor(s).”

That said, the parallel SDT team working on Project 2019-02: BCSI Access Management has proposed language for CIP-011-3, requirement R1, part 1.4 that will require an entity to “identify, assess and mitigate risks” as detailed below:

“Processes to identify, assess, and mitigate risks in cases where vendors store Responsible Entity’s BES Cyber System Information.”

If the intent of this proposal is to require mitigation for all assets under CIP-013, requirement R1, part 1.1, the IRC SRC requests the SDT to:

  • Modify the language under CIP-013-2, requirement R1, part 1.1 to mirror the language proposed under CIP-011-3, requirement R1, part 1.4 OR

Migrate all proposed vendor-related requirements under Project 2019-02; i.e. CIP-011-3, requirement R1, part 1.4, to Project 2019-03: Cyber Security Supply Chain Risks so that they can be addressed collectively under CIP-013-2.

Monika Montez, On Behalf of: California ISO, WECC, Segments 2

- 0 - 0

Joshua Andersen, On Behalf of: Salt River Project, WECC, Segments 1, 3, 5, 6

- 0 - 0

There are cases where the requirements would include “BES Cyber Systems, and their associated EACMS and PACS” as Applicable Systems (such as in CIP-010-4 Part 1.6, CIP-013-2 R1, R1.1, R1.2, R1.2.5). If associated PCAs are not included, the rest of the cyber assets within an Electronic Security Perimeter are also vulnerable. For example, PCA patches may be inadvertently loaded with Trojan Horses, malicious sniffers, etc., which may affect the rest of the devices in the network – including BES Cyber Systems.

Richard Jackson, U.S. Bureau of Reclamation, 1, 3/10/2020

- 0 - 0

Roger Fradenburgh, On Behalf of: Nicholas Lauriat, Network and Security Technologies, 1

- 0 - 0

Andy Fuhrman, On Behalf of: Theresa Allard, Minnkota Power Cooperative Inc., 1

- 0 - 0

Carl Pineault, Hydro-Qu?bec Production, 5, 3/11/2020

- 0 - 0

Ameren agrees with and supports EEI comments.

David Jendras, Ameren - Ameren Services, 3, 3/11/2020

- 0 - 0

Glen Farmer, Avista - Avista Corporation, 5, 3/11/2020

- 0 - 0

Greg Davis, On Behalf of: Georgia Transmission Corporation, , Segments 1

- 0 - 0

Exelon has aligned with EEI's comment in response to this question.

Cynthia Lee, Exelon, 5, 3/11/2020

- 0 - 0

Exelon will align with EEI's comments in response to this question.

Becky Webb, Exelon, 6, 3/11/2020

- 0 - 0

Xcel Energy supports EEI comments on this question. In addition, upon evaluation of the addition of EACMS to CIP-005-6 R2.4 and R2.5, Xcel Energy has recognized that the requirement may limit additional controls to address the risks the requirement part is intended to address.   This situation may create additional administrative burden without the consummate benefits that could be gained through policy or procedural controls.

In CIP-005-6 R2.4 the Requirement states that a Responsible Entity (RE) shall “have one or more methods for determining active vendor remote access sessions (including Interactive Remote Access and system-to-system remote access)”. In CIP-005-6 R2.5 the requirement states that a RE shall “have one or more method(s) to disable active vendor remote access (including Interactive Remote Access and system-to-system remote access).” Both requirements assume that RE have systems that have the capability of Vendor Remote Access (VRA) and that the RE allows for VRA if capability exists.  

Many entities may have systems that are not capable of VRA or do not allow for VRA in their programs. Yet the requirement as written would still force a RE to implement methods to determine VRA sessions and implement methods to disable VRA sessions.

Xcel Energy believes that this issue would be eliminated by adding limited language to the Requirements that reduces the scope to only those REs that allow for VRA.

Xcel Energy proposes adding the following or similar language to achieve this goal:    

 

CIP-005-6 R2.4:

“Where the Responsible Entity permits vendor remote access, have one or more methods for determining active vendor remote access sessions (including Interactive Remote Access and system-to-system remote access).”

 

CIP-005-6 R2.5:

“Where the Responsible Entity permits vendor remote access, have one or more method(s) to disable active vendor remote access (including Interactive Remote Access and system-to-system remote access).”

 

Xcel Energy believes these changes can be made within the scope of the current Standard Authorization Request (SAR). In the purpose section of the SAR the Standard Drafting Team (SDT) is directed to address directives issued by FERC in Order 850 and consider NERC Staff recommendations from the NERC Staff Report. In the Cyber Security Supply Chain Risks Staff Report where they state in the Recommended Actions to Address the Risks section of CH2, P9-10 that recommended actions should “include recommendations to address EACMS risks in the process(es) used to procure BES Cyber Systems that would address identified risks specific to CIP-013-1 Requirement R1 Parts R1.2.1 through R1.2.6, as applicable, and identify existing or planned vendor mitigation strategies or procedures that address each identified risk as follows:”

·         “Specific to CIP-013-1 Requirement R1 Parts R1.2.3 and R1.2.6, include recommendations relative to coordinated controls between the entity and applicable vendors associated with CIP-005-6 (Parts 2.4 and 2.5) for managing active vendor remote access sessions to and/or through EACMS cyber asset types”.

In the process of addressing risk of VRA the SDT should recognize that a VRA risk is being addressed through policy or procedural controls, which current Requirement language does not allow for. If EACMS were included in the scope of the original Supply Chain project this ambiguity in requirement language could have been addressed at that time.

 

 

Amy Casuscelli, On Behalf of: Xcel Energy, Inc. - MRO, WECC - Segments 1, 3, 5, 6

- 0 - 0

1. The IRC SRC recommends the SDT for Project 2019-03: Cyber Security Supply Chain Risks reach out to the SDT for Project 2019-02: BCSI Access Management to explore whether the vendor-related requirements currently proposed under Project 2019-02; i.e. CIP-011-3, requirement R1, part 1.4  “to identify, assess, and mitigate risks in cases where vendors store Responsible Entity’s BES Cyber System Information,” would be a better fit with the existing requirements under CIP-013 and, if so, discuss what would be needed to incorporate those changes into CIP-013-2. Additional support for exploring this recommendation is provided below in the form of a divergence in language between the two SDTs.

2. The IRC SRC requests the SDT collaborate with the SDT for Project 2019-02 to clarify and align the intent of CIP-013-2 requirement R1 with the proposed language for CIP-011-3, requirement R1, part 1.4. Currently, the language of CIP-013-2, R1, part 1.1 only requires an entity to “identify and assess cyber security risks,” there is no mention of mitigation (see excerpt below):

“One or more process(es) used in planning for the procurement of BES Cyber Systems and their associated EACMS and PACS to identify and assess cyber security risk(s) to the Bulk Electric System from vendor products or services resulting from: (i) procuring and installing vendor equipment and software; and (ii) transitions from one vendor(s) to another vendor(s).”

Conversely, the parallel SDT team working on Project 2019-02: BCSI Access Management has proposed language for CIP-011-3, requirement R1, part 1.4 that will require an entity to “identify, assess and mitigate risks in cases where vendors store Responsible Entity’s BES Cyber System Information."

The IRC SRC requests the SDT collaborate with the SDT for Project 2019-02 to clarify and align the intent of this proposal with respect to mitigation:

a. Modify the language under proposed under CIP-011-3, requirement R1, part 1.4 to align with CIP-013-2, requirement R1, part 1.1 OR

b. Migrate all proposed vendor-related requirements under Project 2019-02: BCSI Access Management (i.e. CIP-011-3, requirement R1, part 1.4) to Project 2019-03: Cyber Security Supply Chain Risks so that they can be addressed collectively under CIP-013-2.

The IRC SRC believes the SDT has the latitude under the SAR to undertake this consolidation per the Project Scope:

“This team will work to coordinate with other ongoing CIP development projects to ensure alignment with any changes to definition or standards and requirements."

Note: CAISO (segment 2, WECC region) also joins the IRC SRC in the comments provided in response to Question 6.

ISO/RTO Council Standards Review Committee 2019-03 Supply Chain Risks, Segment(s) 2, 3/11/2020

- 0 - 0

Westar Energy, an Evergy company, supports Edison Electric Institutes responses to Question 6.

Douglas Webb, 3/11/2020

- 0 - 0

Exelon will align with EEI's comments in response to this question.

Kinte Whitehead, Exelon, 3, 3/11/2020

- 0 - 0

PUD No. 1 of Chelan County , Segment(s) 1, 3, 6, 3/11/2020

- 0 - 0

In this draft, the SDT has chosen to include all EACMS while the Commission provided the SDT with enough latitude to include only those EACMS that represent a known risk to the BES. (see Order 850, P51 where the Commission states “[We] leave it to the standard drafting team to assess the various types of EACMS and their associated levels of risks.  We are confident that the standard drafting team will be able to develop modifications that include only those EACMS whose compromise by way of the cybersecurity supply chain can affect the reliable operation of high and medium impact BES Cyber Systems.”)  With this in mind, we encourage the SDT to reevaluate its approach and develop more targeted modification that only address the known risks associated with EACMS that perform the function of controlling electronic access.

In addition to the concerns stated above, EEI also disagrees with the change made to proposed Reliability Standard CIP-005-7, Requirement 2, Subpart 2.5.  While on the surface the change might appear to address the order, the change can be interpreted in such a way that would create an untenable dilemma.  The language can be read to obligate entities to not just terminate vendor access through methods such as disabling rules within a firewall or disabling a user account for EACMS (e.g., Windows domain controller) but also to require entities to block all vendor access to the EACMS itself (i.e., install a firewall for the firewall).  Unfortunately, this solution is unworkable because the new firewall would become a new EACMS obligating the entity to again install another firewall creating an endless loop of new obligations (i.e., you’ve entered the “hall of mirrors”).  To resolve this issue, we recommend simply removing PACS and EACMS from the applicability section of Requirement R2, Subpart 2.5.

EEI also urges the SDT to develop Implementation Guidance for Industry review and comment on the proposed changes.  The changes offered raise many questions on how best to develop and implement solutions that achieve effective compliance.  Such guidance will help entities to better understand the proposed changes offered by the SDT.

Mark Gray, On Behalf of: Edison Electric Institute, NA - Not Applicable, Segments NA - Not Applicable

- 0 - 0

Louisville Gas and Electric Company and Kentucky Utilities Company, Segment(s) 3, 5, 6, 9/6/2018

- 0 - 0

MidAmerican agrees with MRO NSRF comments.

Darnez Gresham, Berkshire Hathaway Energy - MidAmerican Energy Co., 3, 3/11/2020

- 0 - 0

Southern’s comments were detailed in Questions 1-5.

Southern Company, Segment(s) 1, 3, 5, 6, 12/13/2019

- 0 - 0

During our discussion with the SDT SME the SME indicated that mitigation would be required for CIP-013-2 R1 and NPCC request written clarification if mitigation will be required in CIP-013-2 R1.

There is an error in the R3 moderate VSL that was carried over from the previous version.  The existing text reads “…but has performed a vulnerability assessment more than 18 months ….” However, it should read “but has performed a vulnerability assessment more than 18 months, but less than 21 months ….”

RSC, Segment(s) 10, 2, 4, 5, 7, 3, 1, 6, 3/11/2020

- 0 - 0

Mark Ciufo, On Behalf of: Payam Farahbakhsh, Hydro One Networks, Inc., 1,3

- 0 - 0

Eversource Group, Segment(s) 3, 1, 4/12/2019

- 0 - 0

Jeff Icke, Colorado Springs Utilities, 5, 3/11/2020

- 0 - 0

Texas RE seeks clarification as to why PACS and EACMS were not added as applicable systems for Parts 2.1-2.3. In the scenario where a vendor is utilizing Interactive Remote Access (IRA) to a BCA or PCA, Parts 2.1-2.5 would be applicable. However, if the vendor is utilizing IRA to a PACS or EACMS, Parts 2.1-2.3 would not be applicable. This would mean no Intermediate System, no encryption, or multi-factor authentication is required. Texas RE recommends PACS and EACMS should be added.

Rachel Coyne, Texas Reliability Entity, Inc., 10, 3/11/2020

- 0 - 0

Tampa Electric supports the following EEI comments: In this draft, the SDT has chosen to include all EACMS while the Commission provided the SDT with enough latitude to include only those EACMS that represent a known risk to the BES. (see Order 850, P51 where the Commission states “[We] leave it to the standard drafting team to assess the various types of EACMS and their associated levels of risks. We are confident that the standard drafting team will be able to develop modifications that include only those EACMS whose compromise by way of the cybersecurity supply chain can affect the reliable operation of high and medium impact BES Cyber Systems.”) With this in mind, we encourage the SDT to reevaluate its approach and develop more targeted modification that only address the known risks associated with EACMS that perform the function of controlling electronic access.

In addition to the concerns stated above, EEI also disagrees with the change made to proposed Reliability Standard CIP-005-7, Requirement 2, Subpart 2.5. While on the surface the change might appear to address the order, the change can be interpreted in such a way that would create an untenable dilemma. The language can be read to obligate entities to not just terminate vendor access through methods such as disabling rules within a firewall or disabling a user account for EACMS (e.g., Windows domain controller) but also to require entities to block all vendor access to the EACMS itself (i.e., install a firewall for the firewall). Unfortunately, this solution is unworkable because the new firewall would become a new EACMS obligating the entity to again install  another firewall creating an endless loop of new obligations (i.e., you’ve entered the “hall of mirrors”). To resolve this issue, we recommend simply removing PACS and EACMS from the applicability section of Requirement R2, Subpart 2.5.

EEI also urges the SDT to develop Implementation Guidance for Industry review and comment on the proposed changes. The changes offered raise many questions on how best to develop and implement solutions that achieve effective compliance. Such guidance will help entities to better understand the proposed changes offered by the SDT.

Ronald Donahey, TECO - Tampa Electric Co., 3, 3/11/2020

- 0 - 0

None.

LCRA Compliance, Segment(s) 6, 5, 1, 5/11/2015

- 0 - 0

The proposed changes to include EACMS and PAC to the CIP-010-4 requirements seem reasonable, but will add to workload.

Maryanne Darling-Reich, On Behalf of: Black Hills Corporation, MRO, WECC, Segments 1, 3, 5, 6

- 0 - 0

Jesus Sammy Alcaraz, Imperial Irrigation District, 1, 3/11/2020

- 0 - 0

Marc Donaldson, Tacoma Public Utilities (Tacoma, WA), 3, 3/11/2020

- 0 - 0

Support the MRO comments.

Wayne Guttormson, SaskPower, 1, 3/11/2020

- 0 - 0